Star-Hexagon Transformer Supported UPQC
ثبت نشده
چکیده
A new topology of unified power quality conditioner (UPQC) is proposed for different power quality (PQ) improvement in a three-phase four-wire (3P-4W) distribution system. For neutral current mitigation, a star-hexagon transformer is connected in shunt near the load along with three-leg voltage source inverters (VSIs) based UPQC. For the mitigation of source neutral current, the uses of passive elements are advantageous over the active compensation due to ruggedness and less complexity of control. In addition to this, by connecting a star-hexagon transformer for neutral current mitigation the over all rating of the UPQC is reduced. The performance of the proposed topology of 3P-4W UPQC is evaluated for power-factor correction, load balancing, neutral current mitigation and mitigation of voltage and currents harmonics. A simple control algorithm based on Unit Vector Template (UVT) technique is used as a control strategy of UPQC for mitigation of different PQ problems. In this control scheme, the current/voltage control is applied over the fundamental supply currents/voltages instead of fast changing APFs currents/voltages, thereby reducing the computational delay. Moreover, no extra control is required for neutral source current compensation; hence the numbers of current sensors are reduced. The performance of the proposed topology of UPQC is analyzed through simulations results using MATLAB software with its Simulink and Power System Block set toolboxes. Keywords—Power-factor correction, Load balancing, UPQC, Voltage and Current harmonics, Neutral current mitigation, Starhexagon transformer.
منابع مشابه
Improvement of Power Quality Using a Hybrid Interline UPQC
This paper proposed the reduced rating star connected transformer based interline unified power quality conditioner. This work comprises of unified power quality conditioner connected between the two feeders, star connected transformer and LC filter. This hybrid approach significantly improves the performance of UPQC under unbalance source voltage condition. The UPQC adopted to compensate curre...
متن کامل3P-3W UPQC with zig-zag transformer for 3P-4W Distribution System
Abstract: In this paper, a new topology is developed for a three-phase four-wire (3P4W) distribution system utilizing a zig-zag transformer along with three-phase threewire (3P3W) Unified Power Quality Conditioner (UPQC).In this proposed topology the neutral point of the star connected transformer, used for the connection of series active power filter (APF) of 3P3W UPQC, is utilized as a fourth...
متن کاملA New Topology of Three-Phase Four-Wire UPQC with a Simplified Control Algorithm
In this paper, a simplified control algorithm based on unit vector template generation (UVTG) is proposed for a stardelta supported three-phase four-wire (3P-4W) unified power quality conditioner (UPQC) topology for the improvement of different power quality problems. Different topologies reported in literature for 3P-4W UPQC use active compensation for the mitigation of source neutral current ...
متن کاملPower Quality improvement of a three phase four wire system using UPQC
---------------------------------------------------------------------***--------------------------------------------------------------------Abstract This paper presents two different control strategies applied to Unified Power Quality Conditioner (UPQC) to improve power quality in a three-phase, four-wire distribution system. The two control techniques are Unit Vector Template Generation (UVTG)...
متن کاملStudy of Power Quality Improvement Using UPQC
This paper describes role of UPQC as applied to a 3P4W system to improve PQ. The Forth wire of 3P4W system is developed by means of neutral of series transformer. Neutral current which flows through neutral terminal of transformer is removed with the help of 4 leg voltage source inverter (VSI) topology for shunt part. The series transformer neutral will have 0 potential in all conditions of ope...
متن کامل