Limits of multi-linear gradient optimisation in reversed-phase liquid chromatography.

نویسندگان

  • V Concha-Herrera
  • G Vivó-Truyols
  • J R Torres-Lapasió
  • M C García-Alvarez-Coque
چکیده

The concept of limiting peak purity was applied to quantify the degree of completion of the separation capability of a chromatographic system using multi-linear gradients. The objective was to check whether the complexity of a gradient program deserves be increased to enhance resolution by inserting more linear segments, or on the contrary, no significant improvements can be expected under more complex gradients. A set of 19 isoindole derivatives of primary amino acids was selected to test the performance of isocratic, single linear and multi-linear gradients. Accurate simulated chromatograms were obtained via numerical integration of the general equation of gradient elution, using pre-established start and end conditions of the gradient program. The overall peak purity was selected as objective function. Good--although not baseline--resolution was achieved with an optimal trilinear gradient. Excellent agreement between experimental and predicted optimal chromatograms was found. With the proposed approach, a degree of completion of the separation capability of the chromatographic system of 21.2, 49.7, 81.5 and 88.5% was accomplished with optimal gradients with one, two, three and four segments, respectively. More complex gradients did not enhance the latter figure significantly. Also, multi-linear gradients gave rise to more benefits than complementary gradients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

New approach to linear gradient elution used for optimisation in reversed-phase liquid chromatography.

A new mathematical treatment concerning the gradient elution in reversed-phase liquid chromatography when the volume fraction psi of an organic modifier in the water-organic mobile phase varies linearly with time is presented. The experimental ln k versus psi curve, where k is the retention factor under isocratic conditions in a binary mobile phase, is subdivided into a finite number of linear ...

متن کامل

EVALUATION OF THE USE OF ANIONIC/ NONIONIC MIXED MICELLES IN REVERSED PHASE LIQUID CHROMATOGRAPHY OF CHLOROPHENOLS

The use of aqueous mixed micellar system consisting of sodium dodecyl sulfate (SDS) and polyoxyethylene (23) dodecanol (Brij-35) as the mobile phase in reversed-phase liquid chromatography was studied. A group of chlorophenols was used as the test mixture. Adding organic modifier to the system showed that the use of low concentrations of organic additives improves efficiency in SDS/Brij-35 mixe...

متن کامل

Development and Validation of a Reversed-phase HPLC Method for Assay of the Decapeptide Cetrorelix Acetate in Bulk and Pharmaceutical Dosage Forms

A gradient reversed-phase high performance liquid chromatography (HPLC) method was developed for the assay of cetrorelix acetate, a synthetic decapeptide with gonadotropin-releasing hormone (GnRH) antagonistic activity used in infertility treatment. The HPLC method, which is used to determine cetrorelix in bulk and pharmaceutical dosage forms, was validated per ICH guidelines. The chromatograph...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1063 1-2  شماره 

صفحات  -

تاریخ انتشار 2005