Automatic Linearity Calibration in a Resistance

نویسندگان

  • THERMOMETRY BRIDGE
  • Rick Walker
چکیده

The paper describes a new system that automatically calibrates the linearity of a resistance thermometry bridge or readout. A thermometry bridge, like all measuring and test equipment, must be regularly tested to ensure it is operating properly and accurately. Previously, this could only be done using special equipment and time-consuming procedures. The new technique described in the paper facilitates more frequent calibration of a resistance thermometry bridge. The system is incorporated into the design of the bridge and thus requires no extra equipment. Calibration, once initiated, is performed automatically by the bridge and is relatively fast.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic Calibration of HEC-HMS Model Using Multi-Objective Fuzzy Optimal Models

Estimation of parameters of a hydrologic model is undertaken using a procedure called “calibration” in order to obtain predictions as close as possible to observed values. This study aimed to use the particle swarm optimization (PSO) algorithm for automatic calibration of the HEC-HMS hydrologic model, which includes a library of different event-based models for simulating the rainfall-runoff pr...

متن کامل

Report of WHO-sponsored trial of MonA and PotLab colorimeters

The effect of non-linearity of the calibration scale is minimised by its generous length, over 255 mm, and the expansion of the scale divisions in the more critical lower range. Zero adjustment is by mechanical microadjustment which moves the reference cell from the side of the LED.

متن کامل

 A novel approach to automatic position calibration for pixelated crystals in gamma imaging

Introduction: The position estimation in gamma detection system will have constant misplacements which can be corrected in the calibration procedure. In the pixelated crystal uniformly irradiation of detector will produce irregular shape due to position estimation errors. This image is called flood field image and is used to calibrate the position estimation. In this work we pr...

متن کامل

Estimation and Calibration of Robot Link Parameters with Intelligent Techniques

Abstract: Using robot manipulators for high accuracy applications require precise value of the kinematics parameters. Since measurement of kinematics parameters are usually associated with errors and accurate measurement of them is an expensive task, automatic calibration of robot link parameters makes the task of kinematics parameters determination much easier. In this paper a simple and easy ...

متن کامل

New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010