The importance of neo-aortic root geometry in the arterial switch operation with the trap-door technique in the subsequent development of aortic valve regurgitation.

نویسندگان

  • Won Kyoung Jhang
  • Hong Ju Shin
  • Jeong-Jun Park
  • Tae-Jin Yun
  • Young Hwue Kim
  • Jae-Kon Ko
  • In-Sook Park
  • Dong-Man Seo
چکیده

OBJECTIVE Regarding neo-aortic valve regurgitation (neo-AR) after the arterial switch operation (ASO), the 'trap-door' technique was supposed to be a risk factor due to a distortion of the sinotubular junction (STJ) geometry. Here we report our results of the 'trap-door' technique with a special emphasis on root geometry including the ratio of STJ to annulus. METHODS From August 1991 to March 2010, 240 patients with transposition of the great arteries underwent the ASO and who had at least 1 year of follow-up were included in this study. The medical records were retrospectively reviewed. RESULTS The median age and body weight at the time of operation were 11 (0-1213) days and 3.4 (1.30-18.75) kg, respectively. The median follow-up duration was 79 months (range 12 months-19.5 years). At the latest echocardiographic follow-up, only six patients had neo-AR greater than Grade II (6 of 240, 2.5%). We found no relationship between neo-AR greater than Grade II and perioperative factors. The actual sizes of the neo-aortic annulus, mid-sinus and STJ were observed as having increased over time. However, most z-scores of STJ at the latest echocardiography varied between -2 and 2 and, more importantly, the ratio of STJ to neo-aortic annulus was 0.93 ± 0.20, which was near normal at the latest echocardiographic follow-up. CONCLUSIONS Our results showed a very low incidence of significant neo-AR, which was relatively attributable to the preserved z-score of STJ and the normal range of STJ/annulus ratio. Therefore, we propose that it is important to maintain these factors adequately during the reconstruction of the neo-aortic root in the ASO.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva

Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...

متن کامل

Neo-aortic root dilation and valve regurgitation up to 21 years after staged reconstruction for hypoplastic left heart syndrome.

OBJECTIVES We sought to assess the prevalence and progression of neo-aortic root dilation and valvar regurgitation after staged reconstruction for hypoplastic left heart syndrome (HLHS). BACKGROUND In HLHS, the pulmonary valve functions as the neo-aortic valve. Neo-aortic valve dysfunction has been observed after arterial switch operation and the Ross procedure. METHODS Patients with HLHS b...

متن کامل

Long-term predictors of aortic root dilation and aortic regurgitation after arterial switch operation.

BACKGROUND Neo-aortic root dilation (ARD) and neo-aortic regurgitation (AR) may be progressive after arterial switch operation (ASO) for d-loop transposition of the great arteries (dTGA). We sought to identify predictors of ARD and AR after ASO. METHODS AND RESULTS 335 patients were identified who underwent ASO for dTGA with intact ventricular septum or ventricular septal defect (VSD), includ...

متن کامل

Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm

Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...

متن کامل

Aortic regurgitation after arterial switch operation.

n the early 1980s, Jatene developed the arterial switch peration (ASO), which soon became the preferred surgery or d-loop transposition of the great arteries (TGA). This peration includes translocation of the pulmonary artery and orta above the sinuses, often with a Lecompte maneuver bringing the pulmonary artery anterior to the aorta) and oronary reimplantation into the neo-aortic sinuses. Alh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 42 5  شماره 

صفحات  -

تاریخ انتشار 2012