In vitro Evaluation of the Relationship between Gray Scales in Digital Intraoral Radiographs and Hounsfield Units in CT Scans
نویسندگان
چکیده
BACKGROUND Jaw bone quality plays an essential role in treatment planning and prognosis of dental implants. Regarding several available methods for bone density measurements, they are not routinely used before implant surgery due to hard accessibility. OBJECTIVE An in vitro investigation of correlation between average gray scale in direct digital radiographs and Hounsfield units in CT-Scan provides a feasible method for evaluating alveolar bone quality prior to implant surgery. METHODS 26 sheep's mandibles in which a square shape ROI marked by gutta percha, were prepared. Three direct digital radiographs (CCD sensor) from every specimen were taken using 80, 100 and 200 milli-seconds. Then, the average gray levels for ROIs were calculated using a costume-made software. Next, the specimens were scanned using a 16-slice spiral CT and the Hounsfield Unit of each ROI was calculated. Pearson analysis measured the correlation between Hounsfield units and average gray levels. RESULTS There was a positive correlation between Hounsfield unit and average gray level in the radiographs and the correlation was better in higher exposure times. CONCLUSION It is possible to estimate Hounsfield unit and bone density in the jaw bones using average gray scale in a digital radiograph. This approach is easy, simple and available and also results in lower patient exposure comparing other bone densitometric analysis methods.
منابع مشابه
In vitro Evaluation of the Relationship between Gray Scales in Digital Intraoral Radiographs and Hounsfield Units in CT Scans
Background: Jaw bone quality plays an essential role in treatment planning and prognosis of dental implants. Regarding several available methods for bone density measurements, they are not routinely used before implant surgery due to hard accessibility.Objective: An in vitro investigation of correlation between average gray scale in direct digital radiographs and Hounsfield units in CT-Scan pro...
متن کاملEvaluation of the gray level in CBCT systems and its relationship with HU in CT Scanners
Introduction: Cone-beam CT (CBCT) is an imaging system which offers three-dimensional (3D), multiplanar images and has many advantages over computed tomography (CT) including shorter acquisition times for the resolution desired in dentistry, lower radiation dose to the patient, reasonable price and higher spatial resolution but CBCT scanners are unable to display actual Hounsf...
متن کاملComparing the Diagnostic Accuracy of Two Different Resolutions of Radiographs Captured with PSP Digital Intraoral Receptors in Detection of Secondary Caries (In Vitro)
Background and Aim: Considering the importance of detection of secondary caries, the adverse consequences of false positive and false negative diagnoses and the gap of information in the diagnostic efficacy of digital sensors in detection of secondary caries, this in vitro study sought to compare the diagnostic efficacy of two different resolutions of radiographs obtained by photostimulable pho...
متن کاملAn Evaluation of Digital Imaging Studies in an Outpatient Orthopedic Setting
Background: Distribution of radiographic images in the outpatient setting on compact discs-recordable (CD-R) iscommonplace. Opening, manipulating and interpreting these can be challenging. This study evaluated the availabilityand ease of use of CD-R to evaluate digital images in an outpatient orthopedic setting.Methods: 118 CD-R containing diagnostic studies were evaluated by ...
متن کاملRelationship between Hounsfield Unit in CT Scan and Gray Scale in CBCT
Background and aims. Cone-beam computed tomography (CBCT) is an imaging system which has many advantages over computed tomography (CT). In CT scan, Hounsfield Unit (HU) is proportional to the degree of x-ray attenuation by the tissue. In CBCT, the degree of x-ray attenuation is shown by gray scale (voxel value). The aim of the present study was to investigate the relationship between gray scale...
متن کامل