| This paper deals with design improvements on graded insulation of power transformers using transient electric eld analysis and a visualization technique. The calculation method for transient electric eld analysis inside a power transformer impressed with impulse voltage is presented: Initially, the concentrated electric network for the power transformer is constructed by dividing transformer windings into several blocks and by computing the electric circuit parameters. Next, the transient electric eld analysis is performed. Using the results of the circuit analysis as boundary conditions, a 2D axisymmetrical electric eld nite element analysis is performed. Finally, an animated display technique for the transient voltage, the electric eld intensity and the tolerance rate of electric eld intensity distributions is proposed as an extremely useful tool for design on graded insulation. A successful application of the proposed method for analysis of a model transformer for which the computed results agree very well with measured results is also presented. Keywords| Power transformer, graded insulation, impulse voltage, transient electric eld analysis, 2D axisymmetrical nite element method, scienti c visualization.
منابع مشابه
Electric Field Simulations and Analysis for High Voltage High Power Medium Frequency Transformer
The electronic power transformer (EPT) raises concerns for its notable size and volume reduction compared with traditional line frequency transformers. Medium frequency transformers (MFTs) are important components in high voltage and high power energy conversion systems such as EPTs. High voltage and high power make the reliable insulation design of MFT more difficult. In this paper, the influe...
متن کاملModeling the Frequency Response Movements in Power Transformers for Predicting Purposes
Power transformers are key components in electrical power supplies and their failure could cause severe consequences on continuity of service and also generates substantial costs. Identifying problems at an early stage, before catastrophic failure occurs, is a great benefit for reliable operation of power transformers. Frequency Response Analysis (FRA) is a new, well-known and powerful diagnost...
متن کاملSome Precautions for the Field Users of PDC Measurement for Transformer Insulation Condition Assessment
The need for economic, reliable and effective delivery of electric power has lead to the search for new, efficient and effective methods for diagnosing the insulation of the HV equipments in the industries all over the world. One of the methods currently being investigated as a potential nondestructive diagnostic tool for condition monitoring of the oilpaper insulation of power transformers is ...
متن کاملEstimation of Moisture in Transformer Insulation Using Dielectric Frequency Response Analysis by Heuristic Algorithms
Transformers are one of the most valuable assets of power systems. Maintenance and condition assessment of transformers has become one of the concerns of researchers due to huge number of transformers has been approached to the end of their lifetimes. Transformer’s lifetime depends on the life of its insulation and the insulation’s life is strongly influenced by its moisture attraction as well....
متن کاملAnalysis of Electric Field and Polarization of SF6 Circuit Breaker to Approach a Suitable Structure
Abstract: The application of electric field theory to widely different aspects of electrical insulation has led to more understanding the phenomena. Electric fields may be considered as the main reason for insulation failure. The purpose of this paper is to modify importance of analyzing electric field in insulation design. The SF6 circuit breaker is chosen as case study that encounters cri...
متن کامل