Fully automatic, retrospective enhancement of real-time acquired cardiac cine MR images using image-based navigators and respiratory motion-corrected averaging.
نویسندگان
چکیده
Real-time imaging may be clinically important in patients with congestive heart failure, arrhythmias, or in pediatric cases. However, real-time imaging typically has compromised spatial and temporal resolution compared with gated, segmented studies. To combine the best features of both types of imaging, a new method is proposed that uses parallel imaging to improve temporal resolution of real-time acquired images at the expense of signal-to-noise ratio (SNR), but then produces an SNR-enhanced cine by means of respiratory motion-corrected averaging of images acquired in real-time over multiple heartbeats while free-breathing. The retrospective processing based on image-based navigators and nonrigid image registration is fully automated. The proposed method was compared with conventional cine images in 21 subjects. The resultant image quality for the proposed method (3.9+/-0.44) was comparable to the conventional cine (4.2+/-0.99) on a 5-point scale (P=not significant [n.s.]). The conventional method exhibited degraded image quality in cases of arrhythmias whereas the proposed method had uniformly good quality. Motion-corrected averaging of real-time acquired cardiac images provides a means of attaining high-quality cine images with many of the benefits of real-time imaging, such as free-breathing acquisition and tolerance to arrhythmias.
منابع مشابه
High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resorting.
Cine MRI is used for assessing cardiac function and flow and is typically based on a breath-held, segmented data acquisition. Breath holding is particularly difficult for patients with congestive heart failure or in pediatric cases. Real-time imaging may be used without breath holding or ECG triggering. However, despite the use of rapid imaging sequences and accelerated parallel imaging, real-t...
متن کاملReducing the respiratory motion artifacts in PET cardiology: A simulation study
Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...
متن کاملImproved T2-Weighted Cardiac Imaging using Retrospective Motion Correction and Optimal Image Combination
Introduction T2-weighted (T2w) cardiac MR imaging has established reputation as a sensitive technique to depict myocardial edema related to acute infarction. Together with delayed enhancement technique, T2w demonstrated valuable clinical potentials to differentiate acute damage from chronic infarction [1]. To minimize the myocardial signal loss caused by through-plane motion, T2w can be perform...
متن کاملRetrospective reconstruction of high temporal resolution cine images from real-time MRI using iterative motion correction.
Cardiac function has traditionally been evaluated using breath-hold cine acquisitions. However, there is a great need for free breathing techniques in patients who have difficulty in holding their breath. Real-time cardiac MRI is a valuable alternative to the traditional breath-hold imaging approach, but the real-time images are often inferior in spatial and temporal resolution. This article pr...
متن کاملToward a fully automatic left ventricle segmentation using cine-MR images
Left ventricle (LV) function is assessed by manually segmenting short axis cardiac cine magnetic resonance (cine-MR) images. It is a labor, time-consuming, operator biased task. A series of difficulties arise from these images, that make automatic segmentation of the LV a challenging task: (i) misalignment of the LV along the stack, (ii) signal intensity variation over the stack and over the sl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 59 4 شماره
صفحات -
تاریخ انتشار 2008