Newly Designed Sheaths for Gastroduodenal Intervention: An Experimental Study in a Phantom and Dogs

نویسندگان

  • Tae-Seok Seo
  • Ho-Young Song
  • Jong-Heon Lee
  • Gi-Young Ko
  • Kyu-Bo Sung
  • Jin Oh Lim
  • Young Hwan Ko
چکیده

OBJECTIVE To evaluate the usefulness of newly designed sheaths for gastroduodenal intervention in a gastric phantom and dogs. MATERIALS AND METHODS A regular sheath was made using a polytetrafluoroethylene tube (4 mm in diameter, 90 cm long) with a bent tip (4 cm long, 100 degree angle). For the supported type of sheath, a 5 Fr catheter was attached to a regular sheath to act as a side lumen. To evaluate their supportability, we measured the distance of movement of the sheath's tip within a silicone gastric phantom for three types of sheath, the regular type, supported type, and supported type with a supporting guide wire. The experiments were repeated 30 times, and the results were analyzed using ANOVA with the postHoc test. In addition, an animal experiment was performed in six mongrel dogs (total: 12 sessions) to evaluate the torque and supportability of the sheaths in the stomach, while pushing a guide wire or coil catheter under fluoroscopic guidance. RESULTS In the guide wire application, the distances of movement of the sheath tip in the three types of sheath, the regular type, supported type, and supported type with supporting guide wire, were 8.40+/-0.51 cm, 6.23+/-0.41 cm, and 4.47 +/-0.32 cm, respectively (p < 0.001). In the coil catheter application, the corresponding values were 7.22+/-0.70 cm, 5.61+/-0.31 cm and 3.91+/-0.59 cm, respectively (p < 0.001). All three types of sheath rotated smoothly and enabled both the wires and catheters to be guided toward the pylorus of the dog in all cases. CONCLUSION The newly designed sheaths can be useful for gastroduodenal intervention.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Balloon Sheaths for Gastrointestinal Guidance and Access: A Preliminary Phantom Study

OBJECTIVE We wanted to evaluate the feasibility and usefulness of a newly designed balloon sheath for gastrointestinal guidance and access by conducting a phantom study. MATERIALS AND METHODS The newly designed balloon sheath consisted of an introducer sheath and a supporting balloon. A coil catheter was advanced over a guide wire into two gastroduodenal phantoms (one was with stricture and o...

متن کامل

Comparison of the Efficacy of Digital Caliper and a Newly Designed Digital Bone Gauge for Measurement of Edentulous Alveolar Ridge Width

Objectives: An efficient, safe, affordable and easily accessible measuring instrument for quantitative assessment of bone prior to dental implant placement enables more accurate treatment planning. Costly imaging modalities are neither widely available, nor affordable for some patients. This study sought to assess the efficacy of a newly designed digital bone gauge for measurement of bone width...

متن کامل

The Effect of a Designed Care Plan on Mothers’ Performance in Caring for Infants with Pneumonia

Introduction. Most factors which make infants susceptible to pneumonia arise from incorrect infant care in the family and also insufficient knowledge of mothers about correct infant care which makes this problem even worse. The present research was carried out to determine the effect of a Designed Care Plan on mothers' performance in caring for the infants with pneumonia in Children Medical Cen...

متن کامل

تاثیر روش حساسی تزدایی با حرکات چشم و پردازش مجدد بر درد عضو خیالی بیماران تحت قطع عضو

Aim and Background: More than 50% of patients suffer from phantom limb pain after amputation. This study was conducted to identify the effect of eye movement desensitization and reprocessing on phantom limb pain in patients with amputation. Methods and Materials: This quasi experimental study was performed in Yasuj City between 2012 to 2014. A total of forty (40) patients suffering from pha...

متن کامل

Dosimetric Study of an Indigenous and Heterogeneous Pelvic Phantom for Radiotherapy Quality Assurance

Introduction: In vitro dosimetric verification prior to patient treatment plays a key role in accurate and precision radiotherapy treatment delivery. Since the human body is a heterogeneous medium, the aim of this study was to design a heterogeneous pelvic phantom for radiotherapy quality assurance. Material and Methods: A pelvic phantom was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2004