Controller Design for Temperature Control of Heat Exchanger System: Simulation Studies
نویسنده
چکیده
This paper analyzes the performance of different controllers such as feedback, feedback plus feed-forward and internal model controller to regulate the temperature of outlet fluid of a shell and tube heat exchanger to a certain reference value. The transient performance and the error criteria of the controllers are analyzed and the best controller is found out. From the simulation results, it is found out that the internal model control outperforms feedback PID and feedback plus feed-forward controller. Key–Words: Feedback controller, Feedback plus feed-forward controller, internal model controller
منابع مشابه
Analytical and comparative investigations on counter flow heat exchanger using computational fluid dynamics
This paper presents a comprehensive and exclusive thermodynamic analysis of counter flow heat exchanger under various operating and geometrical conditions. Analysis system (ANSYS) workbench 14.0 has been used for computational analysis and comparison with previous literature has been carried out in view of variable temperature and mass flow rate of hot and cold fluids. An analytical and statist...
متن کاملA Double Pipe Heat Exchanger Design and Optimization for Cooling an Alkaline Fuel Cell System
In the presented research, heat transfer of a mobile electrolyte alkaline fuel cell (AFC) (which the electrolyte has cooling role of system) has been considered. Proper control volumes of system with specific qualification have been chosen. Consequently, heat and mass transfer in control volumes have been assessed. Considerations on them and contributed models lead to approve a double tube heat...
متن کاملDesign of Robust PI Controller for Counter-Current Tubular Heat Exchangers
The paper presents an approach for robust PI controller design for a system affected by parametric uncertainty. The method is based on plotting the stability boundary locus in the plane of controller parameters that is called (kp, ki)-plane. Designed robust PI controller is implemented for control of two counter-current tubular heat exchangers in series with uncertain parameters, in which keros...
متن کاملTransient thermal study of recuperative tube in tube heat exchanger operating in refrigeration system using experimental test and mathematical simulation
Joule-Thomson cooling systems are used in refrigeration and liquefaction processes. There are extensive studies on Joule-Thomson cryogenic systems, but most of them coverage steady state conditions or lack from experimental data. In the present work, transient thermal behavior of Joule-Thomson cooling system including counter current helically coiled tube in tube heat exchanger, expansion valve...
متن کاملHow to Design a Cryogenic Joule-Thomson Cooling System: Case Study of Small Hydrogen Liquefier
Heat exchangers are the critical components of refrigeration and liquefaction processes. Selection of appropriate operational conditions for cryogenic recuperative heat exchanger and expansion valve operating in Joule-Thomson cooling system results in improving the performance and efficiency. In the current study, a straightforward procedure is introduced to design an efficient Joule-Thomson co...
متن کامل