Effects of Focus Film Distance (ffd) Variation on Entrance Testicular Dose in Lumbar-pelvic Radiography

نویسندگان

  • Ron Dilger
  • Ingrid Egan
  • Ray Hayek
چکیده

INTRODUCTION With the steady increase in public and professional concern regarding the biological effects of ionising radiation, there is a need for both the Chiropractic and Radiography professions to improve imaging techniques for the lowering of patient radiation doses. Lumbar radiographs are essential in chiropractic general practice for biomechanical diagnosis and postural analysis. Detailed anatomical measurements are taken from spinal radiographs for the determination of various biomechanical alterations for clinical purposes. The quality of spinal radiograph is dependent on a number of factors, including Focus Film Distance (FFD), magnification ratios, penumbra, contrast and density. Variation in FFD will vary magnification factor (MF) and Penumbra. OBJECTIVES The study aims to investigate the relationship between FFD and received radiation dose to patients, where the radiation dose to the testes may be significantly lowered whilst still maintaining acceptable image quality. METHODS Radiographic images and dosimetry were obtained with a Seimans wall-mounted X-ray unit. All anterior/posterior (AP) and lateral lumbar-pelvic radiographs were taken of an anthromorphological phantom that resembles human tissues, at both 100cm and 200cm FFD. Five central beam air doses were measured for all parameters to demonstrate patient entrance doses. RESULTS For AP lumbar-pelvic radiography, increasing FFD by a factor of two resulted in an approximately 30% decrease in entrance dose to the testes. For lateral lumbar-pelvic radiography a two fold increase in FFD resulted in a 70% reduction in entrance dose. CONCLUSIONS The study suggests for the first time that an FFD of 200 cm, which is largely utilised by the chiropractic profession, is an efficient method of minimising radiation dose to patient, during lumbar radiography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy of Increasing Focus to Film Distance (FFD) for Patient’s Dose and Image Quality in Pediatric Chest Radiography

Background: Increasing the x-ray focus to film distance (FFD) has been advocated as an effective method to reduce the patients’ radiation dose. The aim of this study was to investigate the efficacy of this technique in patients' dose and image quality in pediatric chest x-ray.Material and methods: Sixty pediatric patients were x-ray imaged at FFDs of 100 and 130 cm. Dose measurements were perfo...

متن کامل

Optimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD)

Background Increasing the x-ray film to focus distance (FFD), has been recommended as a practical dose optimization tool for patients undergoing conventional radiological procedures. In the previous study, we demonstrated a 32% reduction in absorbed dose is achievable due to increasing the FFD from 100 to 130 cm during pediatric chest radiography. The aim of this study was to examine whether in...

متن کامل

A Phantom Study for the Optimization of Image Quality and Radiation Dose for Common Radiographic Examinations in Digital Radiography

Introduction: Phantom studies facilitate the implementation of radiation dose surveillance as a function of radiographic technical parameters for minimizing patient radiation dose. The evidence of such investigations can then be used to evaluate technical parameters used in the radiographic procedures to reduce radiation dose without compromising the image quality. Material and Methods: This ex...

متن کامل

Effects of Kilovoltage on Image Quality and Entrance Surface Dose in Lumbar Spine Digital Radiography

Introduction: Digital radiography possesses a wide dynamic range and has a major advantage in producing an acceptable image of diagnostic value even though overexposure occurs. Lumbar spine (LS) radiography is the most common examinations that gives high radiation dose to patients and accounts for the highest collective population dose of any conventional radiographic ...

متن کامل

Determination of Diagnostic Reference Level in routine Computed radiography examination in north of Iran

Introduction: Digital radiography has a major role in nowadays healthcare system so radiation protection (justification and optimization) is important in this field. Many related organizations to protection suggested to establish national and regional diagnostic reference level for medical procedures. Reference levels are typically set at the 75th percentile of the dose distri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Australasian Chiropractic & Osteopathy

دوره 6  شماره 

صفحات  -

تاریخ انتشار 1997