Noninvasive monitoring cardiac output using partial CO(2) rebreathing.
نویسندگان
چکیده
This article reviews use of partial carbon dioxide rebreathing devices to determine cardiac output and their application for hemodynamic monitoring in the ICU and operating room. The primary focus is on the NICO monitoring device. Compared with conventional cardiac output methods, these techniques are noninvasive, easily automated, and provide real-time and continuous cardiac output monitoring. The advantages and limitations of each technique are different discussed.
منابع مشابه
Performance of noninvasive partial CO2 rebreathing cardiac output and continuous thermodilution cardiac output in patients undergoing aortic reconstruction surgery.
BACKGROUND In the partial CO(2) rebreathing method, monitored changes in CO(2) elimination and end-tidal CO(2) in response to a brief rebreathing period are used to estimate cardiac output. However, dynamic changes in CO(2) production during ischemia and reperfusion may affect the accuracy of these estimates. This study was designed to compare measurements of cardiac output as produced by the p...
متن کاملEffect of ventilatory settings on accuracy of cardiac output measurement using partial CO(2) rebreathing.
BACKGROUND Recently, a new device has been developed to measure cardiac output noninvasively using partial carbon dioxide (CO(2)) rebreathing. Because this technique uses CO(2) rebreathing, the authors suspected that ventilatory settings, such as tidal volume and ventilatory mode, would affect its accuracy: they conducted this study to investigate which parameters affect the accuracy of the mea...
متن کاملSources of error in noninvasive pulmonary blood flow measurements by partial rebreathing: a computer model study.
BACKGROUND Partial rebreathing is a noninvasive method for measuring pulmonary blood flow (PBF). This study examines the systematic errors produced by the partial rebreathing technique utilizing a comprehensive mathematical model of the cardiorespiratory system of a healthy, 70-kg adult male. METHODS The model simulates tidal breathing through a branched respiratory tree and incorporates the ...
متن کاملReproducibility of noninvasive cardiac output during arm exercise in spinal cord injury.
The carbon dioxide (CO(2)) rebreathing method is a noninvasive technique to estimate cardiac output during exercise, but few data are available on the validity and reliability of this measure in individuals with spinal cord injury (SCI). Sixteen male subjects with SCI (mean age 45 +/- 9, seven paraplegic and nine tetraplegic) underwent three submaximal steady state arm ergometer exercise tests....
متن کاملNoninvasive cardiac output measurement in orthostasis: pulse contour analysis compared with acetylene rebreathing.
We tested the reliability of noninvasive cardiac output (CO) measurement in different body positions by pulse contour analysis (CO(pc)) by using a transmission line model (K. H. Wesseling, B. De Wit, J. A. P. Weber, and N. T. Smith. Adv. Cardiol. Phys. 5, Suppl. II: 16-52, 1983). Acetylene rebreathing (CO(rebr)) was used as a reference method. Twelve subjects (age 21-34 yr) were studied: 1) six...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Critical care clinics
دوره 26 2 شماره
صفحات -
تاریخ انتشار 2010