Clinical Application of a Drill Guide Template for Pedicle Screw Placement in Severe Scoliosis Aplicação Clínica De Matriz De Guia De Broca Para Colocação De Parafuso Pedicular Em Escoliose Grave
نویسندگان
چکیده
Objective: To evaluate the accuracy and the effect of drill guide template for pedicle screw placement in severe scoliosis. Method: Eight patients with rigid scoliosis were enrolled, five males and three females, ranging from nine to 23 years old. A three-dimensional CT scan of the spine was performed and saved as a DICOM file type. The multi-level template was designed by Mimics software and manufactured according to the part of the most severe deformity. The drill template was placed on the corresponding vertebral surface. Pedicle screws were carefully inserted across the trajectory of the template. Postoperatively, the positions of the pedicle screws were evaluated by CT scan and graded for validation. Results: No spinal cord injury or nerve damage occurred. All patients had satisfactory outcomes. The abnormalities and the measures observed during operation were the same as those found in the preoperative period. The position of the pedicle screws was accurate, according to the postoperative X-ray and CT scan. The rate of scoliosis correction was 60%. Compared with controls, surgery time, blood loss and radiation were significantly lower. Conclusion: With the application of multi-level template, the placement of pedicle screws shows high accuracy in scoliosis with shorter surgical time, less blood loss and less radiation exposure. Level of Evidence III, Retrospective Comparative Study.
منابع مشابه
Clinical Application of a Drill Guide Template for Pedicle Screw Placement in Severe Scoliosis
OBJECTIVE To evaluate the accuracy and the effect of drill guide template for pedicle screw placement in severe scoliosis. METHOD Eight patients with rigid scoliosis were enrolled, five males and three females, ranging from nine to 23 years old. A three-dimensional CT scan of the spine was performed and saved as a DICOM file type. The multi-level template was designed by Mimics software and m...
متن کاملA Novel Patient-Specific Drill Guide Template for Pedicle Screw Insertion into the Subaxial Cervical Spine Utilizing Stereolithographic Modelling: An In Vitro Study
STUDY DESIGN Cadaveric study. PURPOSE The purpose of this study was to assess the accuracy and feasibility of cervical pedicle screw (CPS) insertion into the subaxial cervical spine placed using a patient-specific drill guide template constructed from a stereolithographic model. OVERVIEW OF LITERATURE CPS fixation is an invaluable tool for posterior cervical fixation because of its biomecha...
متن کاملPensamento Crítico E Acurácia Dos Diagnósticos De Enfermagem. Parte Ii: Aplicação De Habilidades Cognitivas E Guia Para O Auto-desenvolvimento Pensamiento Crítico Y Precisión De Los Diagnósticos De Enfermería. Ii Parte: Aplicación De Habilidades Cognitivas Y Guia Para El Autodesarrollo
RESUMO Na Parte I deste artigo, o autor explicou as dificuldades em alcançar a acurácia dos diagnósticos de enfermagem, a relevância do pensamento crítico no alcance dessa acurácia e as mais novas perspectivas desse pensamento. Na Parte II, as dimensões do pensamento crítico identificadas como importantes para a prática de enfermagem são aplicadas em um estudo de caso de uma menina de 16 anos c...
متن کاملAccuracy Assessment of Freehand Pedicular Screw Placement
Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...
متن کاملA Modified Personalized Image-Based Drill Guide Template for Atlantoaxial Pedicle Screw Placement: A Clinical Study
BACKGROUND Atlantoaxial posterior pedicle screw fixation has been widely used for treatment of atlantoaxial instability (AAI). However, precise and safe insertion of atlantoaxial pedicle screws remains challenging. This study presents a modified drill guide template based on a previous template for atlantoaxial pedicle screw placement. MATERIAL AND METHODS Our study included 54 patients (34 mal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017