Electronic timing of a high-speed immunonephelometric continuous-flow system.
نویسندگان
چکیده
We describe a high-speed immunoephelometric continuous-flow system. The mechanical timing asembly and cams of the sampler were replaced by an external electronic control unit. Improved sampling precision, speeds of 2 to 900 samples per hour, and a wide variety of sample-to-wash ratios are the most important advantages of the unit. We analyzed albumin and fibrinogen at speeds of 150, 180, and 210 samples per hour. Carry-over studies showed that, in clinical practice, it should be possible to run the system at 150 samples per hour with an interaction of less than 5% and a precision (CV) of around 4%. Comparative studies with a previously described method, run at 60 samples per hour, showed correlation coefficients of 0.968 and 0.935 for albumin and fibrinogen, respectively. The electronic control unit can be used to increase speed and improve sampling precision of any continuous-flow system. An immunonephelometric system equipped with this device provided fast and reliable results, and required less antiserum than other systems described.
منابع مشابه
Flexible Power Electronic Transformer for Power Flow Control Applications
This paper proposes a Flexible Power Electronic Transformer (FPET) for the application in the micro-grids. The low frequency transformer is usually used at the Point of Common Coupling (PCC) to connect the low voltage grid and utility network to each other. The conventional 50Hz transformer results in enhanced low voltage-grid power management system during grid-connected operation. In this pap...
متن کاملPhysical Modeling of Steel Delivery during Thin Slab Continuous Casting
A full scale physical model of a thin slab caster with a four-hole design submerged entry nozzle (SEN) was constructed. On the basis of the dimensionless Reynolds and Froude similitude criteria, the fluid flow in a full-scale model is similar to that of the actual system and, hence, the data obtained from the water model can be applied to the actual system. In order to determine the optimum ope...
متن کاملAnalysis of air injection system for drag reduction in high speed vessels using numerical simulation software ANSYS-Fluid Flow
Many existing phenomena in nature are considered new design ideas in various fields of industry. Bionics is the application of biological methods and systems found in nature to the study and design of engineering systems and modern technology. By performing bionic review, the researchers found the penguins by delivering air locked under their wings and creating air bubbles, the drag significant...
متن کاملLiquid Fuel Production from Synthesis Gas via Fermentation Process in a Continuous Tank Bioreactor (CSTBR) Using Clostridium ljungdahlii
The potential bioconversion of synthesis gas (syngas) to fuels and chemicals by microbial cell has attracted considerable attention in past decade. The feasibility of enhancing syngas bioconversion to ethanol and acetate using Clostridium ljungdahlii in a continuous tank bioreactor (CSTBR), kinetics and mass transfer coefficient of carbon monoxide (CO) utilization were evaluated. Two different ...
متن کاملانتقال حرارت در جریان پیوستۀ دوگانۀ دو مایع امتزاجناپذیر
In this study, heat transfer coefficients are measured for diesel-water two-phase flow in a horizontal pipe for dual continuous, dispersion of oil in water and dispersion of water in oil flow patterns. Flow patterns are observed using high speed photography for diesel-water mixture and two phase heat transfer data are obtained under a uniform heat flux boundary condition. The test section is a ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 21 6 شماره
صفحات -
تاریخ انتشار 1975