Novel method for delivering the Amplatzer muscular VSD occluder in a patient with double outlet right ventricle after bidirectional Glenn procedure and pulmonary artery band.

نویسندگان

  • Martin L Bocks
  • Aimee K Armstrong
چکیده

We report the first use of bilateral femoral venovenous rail creation for the delivery of an Amplatzer Muscular Ventricular Septal Defect Occluder in a patient with a large mid-to-apical muscular ventricular septal defect before Rastelli operation. The presence of a right-sided bidirectional Glenn shunt, a banded main pulmonary artery, and double outlet right ventricle anatomy precluded the use of standard delivery techniques. The patient underwent successful transcatheter device placement followed by Rastelli operation on the following day.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter closure of post-operative residual ventricular septal defect using a patent ductus arteriosus closure device in an adult: a case report.

Transcatheter closure of perimembranous and muscular ventricular septal defect (VSD) has been performed widely and it has more advantages compare to surgery. However, transcatheter closure of residual VSD post operation of complex congenital heart disease is still challenging because of the complexity of anatomy and concern about device stability, so the operator should meticulously choose the ...

متن کامل

A novel use of an Amplatzer septal occluder.

A 4 year old girl with an underlying diagnosis of atrioventricular discordance, double outlet right ventricle with pulmonary valvar atresia, and subpulmonary ventricular septal defect, was admitted for elective surgery. She had had surgery as a neonate to insert a right 5 mm Gore-tex modified Blalock Taussig shunt, and again at 3 years old for formation of a bidirectional Glenn anastomosis. Car...

متن کامل

Rapid development of a large systemic-to-pulmonary vein fistula after bidirectional Glenn shunt and successful closure with an Amplatzer duct occluder.

A7-month-old boy presented with significant cyanosis 17 days after bidirectional cavopulmonary shunting (Glenn procedure). He had previously undergone a Norwood operation at 7 days of age for a double-outlet right ventricle with hypoplastic left ventricle, hypoplastic aortic arch, and coarctation. Cardiac catheterization 10 days before the Glenn operation showed a pulmonary venous wedge pressur...

متن کامل

[Percutaneous closure of ventricular septal defect with an Amplatzer device].

We present a series of 4 patients in whom a ventricular septal defect (VSD) was closed with an Amplatzer muscular VSD device during cardiac catheterization. In one patient with type I truncus arteriosus and subarterial VSD, closure of a wide apical defect was done to allow further surgical correction while avoiding left ventricular ventriculotomy. The second patient had congenitally corrected t...

متن کامل

Percutaneous closure of post-traumatic and congenital muscular ventricular septal defects with the Amplatzer Muscular VSD Occluder.

BACKGROUND Muscular ventricular septal defects (VSD) are an important and difficult surgical problem. In the last few years a new alternative has emerged - possibility of VSD closure using percutaneous approach. AIM To present our experience in percutaneous closure of congenital muscular and one posttraumatic VSD. METHODS We treated 10 patients - 7 children (age 0.8-7 years) and 2 adults (4...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions

دوره 74 3  شماره 

صفحات  -

تاریخ انتشار 2009