Quantification of the effect of cross-shear and applied nominal contact pressure on the wear of moderately cross-linked polyethylene.

نویسندگان

  • Abdellatif Abdelgaied
  • Claire L Brockett
  • Feng Liu
  • Louise M Jennings
  • John Fisher
  • Zhongmin Jin
چکیده

Polyethylene wear is a great concern in total joint replacement. It is now considered a major limiting factor to the long life of such prostheses. Cross-linking has been introduced to reduce the wear of ultra-high-molecular-weight polyethylene (UHMWPE). Computational models have been used extensively for wear prediction and optimization of artificial knee designs. However, in order to be independent and have general applicability and predictability, computational wear models should be based on inputs from independent experimentally determined wear parameters (wear factors or wear coefficients). The objective of this study was to investigate moderately cross-linked UHMWPE, using a multidirectional pin-on-plate wear test machine, under a wide range of applied nominal contact pressure (from 1 to 11 MPa) and under five different kinematic inputs, varying from a purely linear track to a maximum rotation of +/- 55 degrees. A computational model, based on a direct simulation of the multidirectional pin-on-plate wear tester, was developed to quantify the degree of cross-shear (CS) of the polyethylene pins articulating against the metallic plates. The moderately cross-linked UHMWPE showed wear factors less than half of that reported in the literature for, the conventional UHMWPE, under the same loading and kinematic inputs. In addition, under high applied nominal contact stress, the moderately crosslinked UHMWPE wear showed lower dependence on the degree of CS compared to that under low applied nominal contact stress. The calculated wear coefficients were found to be independent of the applied nominal contact stress, in contrast to the wear factors that were shown to be highly pressure dependent. This study provided independent wear data for inputs into computational models for moderately cross-linked polyethylene and supported the application of wear coefficient-based computational wear models.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization and quantification of the cross-linking of linear low density polyethylene with silane grafting by Fourier transform infrared (FTIR) spectroscopy

The way of making cross-linkable polyethylene through silane grafting has gained much attention in recentyears because of its various advantages such as easy processing, low cost and capital investment andfavorable properties in the processed materials. This work deals with silane grafting and moisture crosslinkingof linear low density polyethylene (LLDPE). The grafting reaction was performed i...

متن کامل

Wear of moderately cross-linked polyethylene fixed bearing knee replacements

Cross-linked polyethylene has been explored as an alternative to conventional polyethylene in total joint replacement in order to reduce wear volume and decrease failure through polyethylene wear debris induced osteolysis [1]. Due to the demands of a total knee replacement, moderately cross-linked polyethylene is recommended to retain mechanical properties [2]. This study aims to investigate th...

متن کامل

The effect of insert conformity and material on total knee replacement wear

The mean average life is increasing; therefore, there is a need to increase the lifetime of the prostheses. To fulfil this requirement, new prosthetic designs and materials are being introduced. Two of the design parameters that may affect wear of total knee replacements, and hence the expected lifetime, are the insert conformity and material. Computational models have been used extensively for...

متن کامل

Influence of contact pressure, cross-shear and counterface material on the wear of PEEK and CFR-PEEK for orthopaedic applications

Total joint replacement is a successful surgical intervention for the treatment of the degeneration of many joints, particularly the hip and knee. As the demand for joint replacement grows, and the life expectancy of the population increases, the performance requirements of these implants also changes. New materials, to improve longevity and enhance performance have been explored including PEEK...

متن کامل

Investigating the Effect of Using Cross-Linked Polyethylene Waste as Fine Aggregate on Mechanical Properties of Hot Mix Asphalt

Cross-linked polyethylene (XLPE) is an appropriate insulating material for high-voltage cables which has been widely used as electrical cable coating. In this study, Crushed XLPE wastes with different volume percentages (25, 50, and 75%) were used in hot mix asphalt (HMA) as a substitute for fine aggregates remained on sieve no. 8 whose size varies from 1.18 to 2.36 mm. The dynamic stiffness (i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine

دوره 227 1  شماره 

صفحات  -

تاریخ انتشار 2013