Plastic scintillator detectors have been studied as dosimeters, since they provide a cost-effective alternative to conventional ionization chambers. On the other hand, several articles have reported undesired response dependencies on beam energy and temperature, which enhances the necessity to determine appropriate correction factors. In this work, we studied the light yield temperature dependency of four plastic scintillators (BCF-10, BCF-60, BC-404 and RP-200A) and two clear fibers (BCF-98 and SK-80). Measurements were made using a 50 kVp X-ray beam to produce the scintillation and/or radioluminescence signal. The 0 to 40 oC temperature range was scanned for each scintillator, and temperature coefficients obtained.
منابع مشابه
Optical simulation and experimental measurement of gamma ray energy spectrum of plastic scintillators with different sizes
The application of large plastic scintillators is widely increasing in the different areas of industry, medicine and security due to technical and economic advantages. One of the main disadvantages of these detectors is the unknown position of Compton edge at gamma ray spectrum. In this research, GEANT4/GATE code has been used to simulate the gamma ray spectrum for different volumes of large pl...
متن کاملMonte Carlo calculations of the absorbed dose and energy dependence of plastic scintillators.
Detector systems using plastic scintillators can provide instantaneous measurements with high spatial resolution in many applications including small field and high dose gradient field applications. Energy independence and water equivalence are important dosimetric properties that determine whether a detector will be useful in a clinical setting. Using Monte Carlo simulations, we calculated the...
متن کاملInvestigation of the Temperature Dependence of Free Volume in Polymethylpentene by Positron Annihilation Method
Positron lifetime measurements in polymethylpentene were performed in a wide temperature range. A conventional fast–slow coincidence lifetime spectrometer with plastic scintillators was used. All the measurements were made in vacuum. Additional measurements (X-ray diffraction, differential scanning calorimetry, and mechanical spectroscopy) were also performed to establish properties of samples....
متن کاملPlastic gamma sensors: an application in detection of radioisotopes
A brief survey of plastic scintillators for various radiation measurement applications is presented here. The utility of plastic scintillators for practical applications such as gamma radiation monitoring, real-time radioisotope detection and screening is evaluated in laboratory and field measurements. This study also reports results of Monte Carlo-type predictive responses of common plastic sc...
متن کاملPlastic scintillators for positron emission tomography obtained by the bulk polymerization method
This paper describes three methods regarding the production of plastic scintillators. One method appears to be suitable for the manufacturing of plastic scintillators, revealing properties which fulfill the requirements of novel positron emission tomography scanners based on plastic scintillators. The key parameters of the manufacturing process are determined and discussed.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -