Reactive intermediate detection in real time via paper assisted thermal ionization mass spectrometry.

نویسندگان

  • Jiying Pei
  • Yanbiao Kang
  • Guangming Huang
چکیده

To capture reactive intermediates from bulk solution in real time, mass spectrometry with paper assisted thermal ionization has been developed. Two representative organic reactions, Eschweiler-Clarke methylation at high temperature and acid-catalyzed olefin dioxygenation at room temperature, were chosen as models to evaluate the present method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real time monitoring of accelerated chemical reactions by ultrasonication-assisted spray ionization mass spectrometry.

Ultrasonication has been used to accelerate chemical reactions. It would be ideal if ultrasonication-assisted chemical reactions could be monitored by suitable detection tools such as mass spectrometry in real time. It would be helpful to clarify reaction intermediates/products and to have a better understanding of reaction mechanism. In this work, we developed a system for ultrasonication-assi...

متن کامل

The expanding role of electrospray ionization mass spectrometry for probing reactive intermediates in solution.

Within the past decade, electrospray ionization mass spectrometry (ESI-MS) has rapidly occupied a prominent position for liquid-phase mechanistic studies due to its intrinsic advantages allowing for efficient "fishing" (rapid, sensitive, specific and simultaneous detection/identification) of multiple intermediates and products directly from a "real-world" solution. In this review we attempt to ...

متن کامل

Advanced oxidation of caffeine in water: on-line and real-time monitoring by electrospray ionization mass spectrometry.

High performance liquid chromatography (HPLC), ultraviolet spectroscopy (UV), and total organic carbon (TOC) analyses show that caffeine is quickly and completely degraded underthe oxidative conditions of the UV/H2O2,TiO2/ UV, and Fenton systems but that the organic carbon content of the solution decreases much more slowly. Continuous on-line and real-time monitoring by electrospray ionization ...

متن کامل

Matrix-assisted laser desorption/ionization time-of-flight intact cell mass spectrometry to detect emerging pathogenic Candida species.

Matrix-assisted laser desorption/ionization time-of-flight intact cell mass spectrometry (MALDI-TOF-ICMS) was used to differentiate pathogenic Candida species, difficult to identify by traditional methods such as growth and biochemical reactions. Results showed that species complexes like C. parapsilosis, C. orthopsilosis, and C. metapsilsosis, and very closely related species like C. glabrata ...

متن کامل

Electron-transfer-catalyzed dimerization of trans-anethole: detection of the distonic tetramethylene radical cation intermediate by extractive electrospray ionization mass spectrometry.

The desolvating droplets of EESI were used as microreactor for the mass spectrometric study of short-lived transients of reactions in condensed liquid phase in the millisecond time region. The electron-transfer-catalyzed dimerization of trans-anethole was investigated and the intermediates in the radical cation chain reaction were isolated and characterized by MS-MS. The distonic tetramethylene...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 139 21  شماره 

صفحات  -

تاریخ انتشار 2014