Quantitative mouse renal perfusion using arterial spin labeling.
نویسندگان
چکیده
Information on renal perfusion is essential for the diagnosis and prognosis of kidney function. Quantification using gadolinium chelates is limited as a result of filtration through renal glomeruli and safety concerns in patients with kidney dysfunction. Arterial spin labeling MRI is a noninvasive technique for perfusion quantification that has been applied to humans and animals. However, because of the low sensitivity and vulnerability to motion and susceptibility artifacts, its application to mice has been challenging. In this article, mouse renal perfusion was studied using flow-sensitive alternating inversion recovery at 7 T. Good perfusion image quality was obtained with spin-echo echo-planar imaging after controlling for respiratory, susceptibility and fat artifacts by triggering, high-order shimming and water excitation, respectively. High perfusion was obtained in the renal cortex relative to the medulla, and signal was absent in scans carried out post mortem. Cortical perfusion increased from 397 ± 36 (mean ± standard deviation) to 476 ± 73 mL/100 g/min after switching from 100% oxygen to carbogen with 95% oxygen and 5% carbon dioxide. The perfusion in the medulla was 2.5 times lower than that in the cortex and changed from 166 ± 41 mL/100 g/min under oxygen to 203 ± 40 mL/100 g/min under carbogen. T1 decreased in both the cortex (from 1570 ± 164 to 1377 ± 72 ms, p < 0.05) and medulla (from 1788 ± 107 to 1573 ± 144 ms, p < 0.05) under carbogen relative to 100% oxygen. The results showed the potential of the use of ASL for perfusion quantification in mice and in models of renal diseases.
منابع مشابه
Renal perfusion imaging with two-dimensional navigator gated arterial spin labeling.
PURPOSE To develop a navigator technique enabling free-breathing acquisition to afford sufficient signal averaging for quantitative renal perfusion measurement using arterial spin labeling MRI. METHODS A novel two-dimensional (2D) navigator technique was implemented in concert with flow-sensitive alternating inversion recovery (FAIR) preparation and true fast imaging with steady precession (T...
متن کاملNon-Invasive Renal Perfusion Imaging Using Arterial Spin Labeling MRI: Challenges and Opportunities
Tissue perfusion allows for delivery of oxygen and nutrients to tissues, and in the kidneys is also a key determinant of glomerular filtration. Quantification of regional renal perfusion provides a potential window into renal (patho) physiology. However, non-invasive, practical, and robust methods to measure renal perfusion remain elusive, particularly in the clinic. Arterial spin labeling (ASL...
متن کاملRenal Perfusion Imaging using Continuous Arterial Spin Labeling with Separate Labeling and Imaging Coils
Introduction: Assessment of renal perfusion rates can provide important information about kidney function, but also about diseases with pathological perfusion changes, e.g. nephrocalcinosis and renal infarction. To minimize potential risks of nephrotoxicity associated with Gd-based MR perfusion techniques, arterial spin labeling (ASL) is currently being adapted to the kidneys [1-3]. ASL, a meth...
متن کاملA theoretical and experimental comparison of continuous and pulsed arterial spin labeling techniques for quantitative perfusion imaging.
Under ideal conditions, continuous arterial spin labeling (ASL) techniques are higher in SNR than pulsed ASL techniques by a factor of e. Presented here is a direct theoretical and experimental comparison of continuous ASL and pulsed ASL, using versions of both that are amenable to multislice imaging and insensitive to variations in transit times (continuous ASL with a delay before imaging, and...
متن کاملFunctional MRI for characterization of renal perfusion impairment and edema formation due to acute kidney injury in different mouse strains
PURPOSE The purpose was to characterize acute kidney injury (AKI) in C57BL/6 (B6)- and 129/Sv (Sv)-mice by noninvasive measurement of renal perfusion and tissue edema using functional MRI. METHODS Different severities of AKI were induced in B6- and Sv-mice by renal ischemia reperfusion injury (IRI). Unilateral clamping of the renal pedicle for 35 min (moderate AKI) or 45 min (severe AKI) was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- NMR in biomedicine
دوره 26 10 شماره
صفحات -
تاریخ انتشار 2013