Electrogram fractionation: the relationship between spatiotemporal variation of tissue excitation and electrode spatial resolution.

نویسندگان

  • Daniel D Correa de Sa
  • Nathaniel Thompson
  • Justin Stinnett-Donnelly
  • Pierre Znojkiewicz
  • Nicole Habel
  • Joachim G Müller
  • Jason H T Bates
  • Jeffrey S Buzas
  • Peter S Spector
چکیده

BACKGROUND Fractionated electrograms are used by some as targets for ablation in atrial and ventricular arrhythmias. Fractionation has been demonstrated to result when there is repetitive or asynchronous activation of separate groups of cells within the recording region of a mapping electrode(s). METHODS AND RESULTS Using a computer model, we generated tissue activation patterns with increasing spatiotemporal variation and calculated virtual electrograms from electrodes with decreasing resolution. We then quantified electrogram fractionation. In addition, we recorded unipolar electrograms during atrial fibrillation in 20 patients undergoing atrial fibrillation ablation. From these we constructed bipolar electrograms with increasing interelectrode spacing and quantified fractionation. During modeling of spatiotemporal variation, fractionation varied directly with electrode length, diameter, height, and interelectrode spacing. When resolution was held constant, fractionation increased with increasing spatiotemporal variation. In the absence of spatial variation, fractionation was independent of resolution and proportional to excitation frequency. In patients with atrial fibrillation, fractionation increased as interelectrode spacing increased. CONCLUSIONS We created a model for distinguishing the roles of spatial and temporal electric variation and electrode resolution in producing electrogram fractionation. Spatial resolution affects fractionation attributable to spatiotemporal variation but not temporal variation alone. Electrogram fractionation was directly proportional to spatiotemporal variation and inversely proportional to spatial resolution. Spatial resolution limits the ability to distinguish high-frequency excitation from overcounting. In patients with atrial fibrillation, complex fractionated atrial electrogram detection varies with spatial resolution. Electrode resolution must therefore be considered when interpreting and comparing studies of fractionation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Relationship Between Spatiotemporal Variation of Tissue Excitation and Electrode Spatial Resolution

Background—Fractionated electrograms are used by some as targets for ablation in atrial and ventricular arrhythmias. Fractionation has been demonstrated to result when there is repetitive or asynchronous activation of separate groups of cells within the recording region of a mapping electrode(s). Methods and Results—Using a computer model, we generated tissue activation patterns with increasing...

متن کامل

Revealing the impact of changing land use of the annual spatiotemporal boundary layer height (Kermanshah Case Study)

Introduction Atmospheric boundary layer (ABL), is the lowest part of the atmosphere. Its behavior is directly influenced by its contact with earth surface. On earth it usually responds to changes in surface radiative forcing in an hour or less. In this layer physical quantities such as flow velocity, temperature, moisture, etc., display rapid fluctuations (turbulence) and vertical mixing is st...

متن کامل

Spatiotemporal Assessment of Groundwater Quality and Quantity Variation in Mallard County, Tehran

Deficiency of water with suitable quality is a vital challenge in urban and specially in arid and semiarid regions. The aim of this study is to assess temporal and spatial variation of drinking groundwater quality and quantity in County of Mallard in Tehran province. Mallard is a County at margin of Central Iran Plateau. The data used in this research comprises of 14 parameters in 31 drinking w...

متن کامل

Spatial reproducibility of complex fractionated atrial electrogram depending on the direction and configuration of bipolar electrodes: an in-silico modeling study

Although 3D-complex fractionated atrial electrogram (CFAE) mapping is useful in radiofrequency catheter ablation for persistent atrial fibrillation (AF), the directions and configuration of the bipolar electrodes may affect the electrogram. This study aimed to compare the spatial reproducibility of CFAE by changing the catheter orientations and electrode distance in an in-silico left atrium (LA...

متن کامل

Investigation of the effect of source distance and scattering medium on spatial resolution and contrast of Gamma camera images [Persian]

By identifying the effect of any parameter such as distance, attenuation and scattering on the Line Spread Function (LSF), one can compensate the quantitative and qualitative destructive effect of such parameters by deconvolution method. Using a 99mTC line source, this study was performed on a single head ADAC SPECT system operating in planar mode. Variation of FWTM and FWHM and LSFs as a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 4 6  شماره 

صفحات  -

تاریخ انتشار 2011