A Comparison between 2d and 3d Surface Parameters for Evaluating the Quality of Surfaces
نویسندگان
چکیده
This paper presents a comparison of the results for roughness parameters obtained with the help of two methods of evaluating the quality of the finished surfaces: 2D profilometry and 3D profilometry. There were investigated square areas from finished steel rings and polymeric blocks, these elements being used for tests on a block-on-ring tribotester. There were calculated the average values of the 3D parameters characterizing three square areas on each part and the average values of nine 2D profiles extracted from the already investigated square areas. There were also discussed the scattering ranges for the roughness parameters as given by each of the two methods. When evaluating the worn surfaces, the parameters Ssk, Sku, Sy, Sp are Sv, are more relevant, as the high peaks affect the tribological parameters, especially when dealing with polymeric composites.
منابع مشابه
Investigation the Milling Strategies Effects on Machining of Convex Surfaces made of Glass/Epoxy Composite
In this study the effects of machining parameters such as shearing speed, feed rate, tool diameter and machining depth on different milling strategies i.e. 3D offset, spiral, raster and radial to produce the convex surface made of epoxy/glass composites is investigated. The effects of mentioned strategies on output parameters such as surface roughness and milling removal rate is also studied. T...
متن کاملExternal radiotherapy of intact breast: A comparison between 2D (single CT- slice) and 3D (full CT-slices) plans
Background: Tangential irradiation of intact breast is one of the most common procedures performed in any radiotherapy center. This method is performed by using 2D and 3D treatment planning. The aim of this study was to compare 2D with 3D plans in breast conserving radiotherapy. Homogeneity of isodose, and lung received dose were compared. Materials and Methods: Twenty patients with br...
متن کاملA New Approach for Quantitative Evaluation of Reconstruction Algorithms in SPECT
ABTRACT Background: In nuclear medicine, phantoms are mainly used to evaluate the overall performance of the imaging systems and practically there is no phantom exclusively designed for the evaluation of the software performance. In this study the Hoffman brain phantom was used for quantitative evaluation of reconstruction techniques. The phantom is modified to acquire t...
متن کاملEvaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT
Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...
متن کاملStudy of Sexual Dimorphism in Second-to-fourth Digit Length Ratio (2D: 4D) in the Green-Bellied Lizard (Darevskia cholorogaster) from Iran
Sexual dimorphism in digit ration is related to genetic differences between species in response to prenatal exposure to hormones. In this study, the development of tetrapod digits, preliminary the ratio between the length of digit II and IV (2D: 4D) was investigated in 34 samples of Darevskia cholorogaster in the North of Iran. The results showed no significant differences between sexes in any ...
متن کامل