Effect of limbal marking prior to laser ablation on the magnitude of cyclotorsional error.

نویسندگان

  • Xiangjun Chen
  • Aleksandar Stojanovic
  • Filip Stojanovic
  • Jon Roger Eidet
  • Sten Raeder
  • Haakon Øritsland
  • Tor Paaske Utheim
چکیده

PURPOSE To evaluate the residual registration error after limbal-marking-based manual adjustment in cyclotorsional tracker-controlled laser refractive surgery. METHODS Two hundred eyes undergoing custom surface ablation with the iVIS Suite (iVIS Technologies) were divided into limbal marked (marked) and non-limbal marked (unmarked) groups. Iris registration information was acquired preoperatively from all eyes. Preoperatively, the horizontal axis was recorded in the marked group for use in manual cyclotorsional alignment prior to surgical iris registration. During iris registration, the preoperative iris information was compared to the eye-tracker captured image. The magnitudes of the registration error angle and cyclotorsional movement during the subsequent laser ablation were recorded and analyzed. RESULTS Mean magnitude of registration error angle (absolute value) was 1.82°±1.31° (range: 0.00° to 5.50°) and 2.90°±2.40° (range: 0.00° to 13.50°) for the marked and unmarked groups, respectively (P<.001). Mean magnitude of cyclotorsional movement during the laser ablation (absolute value) was 1.15°±1.34° (range: 0.00° to 7.00°) and 0.68°±0.97° (range: 0.00° to 6.00°) for the marked and unmarked groups, respectively (P=.005). Forty-six percent and 60% of eyes had registration error >2°, whereas 22% and 20% of eyes had cyclotorsional movement during ablation >2° in the marked and unmarked groups, respectively. CONCLUSIONS Limbal-marking-based manual alignment prior to laser ablation significantly reduced cyclotorsional registration error. However, residual registration misalignment and cyclotorsional movements remained during ablation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical effects of pure cyclotorsional errors during refractive surgery.

PURPOSE To describe the theoretical effects of cyclotorted ablations on induced aberrations and determine the limits of tolerance of cyclotorsional accuracy. METHODS A method was developed to determine the average cyclotorsion during refractive surgery without a cyclotorsion tracker. Mathematical conditions were simulated to determine the optical, visual, and absolute benefits in 76 consecuti...

متن کامل

CT-guided laser probe for ablation of brain tumors

In this study, 22 patients (15-75 years old) were selected and transferred to CT scan for tumor ablation. For ablations, after prep and drep under the local anesthesia and mild sedation in proper position, small incision made and special needle inserted and guided by proper direction to the core of the tumor. Then, laser probe inserted through the needle and laser energy delivered. Although we ...

متن کامل

Feasibility Assessment of Optical Coherence Tomography-Guided Laser Labeling in Middle Cranial Fossa Approach

Introduction: Different approaches have been developed to find the position of the internal auditory canal (IAC)in middle cranial fossa approach. A feasibility study was performed to investigate the combination of cone beam computed tomography (CBCT), optical coherence tomography (OCT), and laser ablation to assist a surgeon in a middle cranial fossa approach by outlining the internal auditory ...

متن کامل

Study of laser ablation using nano-second laser pulses

 In this paper, the laser ablation process based on the irradiation of nanosecond pulsed lasers on a copper target surface in the presence of Helium gas is studied. The dynamical behaviors of the generated plasma in the helium gas and evaporated copper at the atmospheric pressure are examined using a laser pulse, laser wavelength of and intensity of 7×1010W/cm2. A one-dimensional thermal model ...

متن کامل

بررسی برهمکنش لیزر Er,Cr:YSGG با بافت سخت دندان

Background and Aims: Nowadays lasers are used as alternatives to the tooth preparation because of reducing pain, bloodshed and stress. The aim of this study was to observe the effect of Er,Cr:YSGG laser on the dental hard tissues. Materials and Methods: For this studty, molar teeth with no caries or dental restoration and enamel cracks were used. The laser power were taken from 0.5, 1, 1.5, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 28 5  شماره 

صفحات  -

تاریخ انتشار 2012