Measuring Reflective Properties of PTFE for Applications in Liquid Xenon Detectors

نویسنده

  • Catherine Lussenhop
چکیده

The XENON100 experiment uses 161kg of liquid xenon divided in two concentric cylinders. The inner volume is the time-projection chamber, the outer volume is the veto, and they are separated by PTFE (Teflon) panels. In the region 350nm to 1200nm, PTFE has a measured reflectivity of 99%. However, xenon emits in the UV region, and the reflectivity distribution is not sufficiently understood here. The XENON group uses a vacuum spectrograph to attempt to determine a reflection distribution for the PTFE that encloses the XENON100 TPC. The spectrograph will be used to measure a reflectivity distribution for the type of PTFE used in the detector. Measurements will be repeated after the PTFE sample is cooled to deduce the effect of low temperature on the reflectivity distribution. In the future, this same tool can also be used to determine how low temperatures affect the quantum efficiency of the PMTs used in the XENON100 experiment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring the angular profile of the reflection of xenon scintillation light

A chamber designed for measuring the angular distribution of reflected ultraviolet vacuum light is described. We report first measurements of the reflection profile of xenon scintillation light by a polished copper surface and by polytetrafluoroethylene (PTFE). r 2007 Elsevier B.V. All rights reserved. PACS: 78.20.Ci; 29.40.M

متن کامل

s . in s - de t ] 3 A ug 2 00 6 Gamma Ray Spectroscopy with Scintillation Light in Liquid Xenon

Scintillation light from gamma ray irradiations in liquid xenon is detected by two Hamamatsu R9288 photomultiplier tubes (PMTs) immersed in the liquid. UV light reflector material, PTFE, is used to optimize the light collection efficiency. The detector gives a high light yield of 6 photoelectron per keV (pe/keV), which allows efficient detection of the 122 keV γ-ray line from 57 Co, with a good...

متن کامل

Gas/Liquid and Liquid/Liquid Solvent Extraction in Flow Analysis with the Chromatomembrane Cell

Since twelve years the Chromatomembrane Cell has been proposed as a new and versatile device for extraxtion procedures in the flow based analysis. In the meantime a remarkable number of papers was submitted dealing with applications of the novel method to all the conceivable varieties of flow injection and sequential injection analysis. The device supports important analytical procedures such a...

متن کامل

Preparation of Neutron-activated Xenon for Liquid Xenon Detector Calibration

We report the preparation of neutron-activated xenon for the calibration of liquid xenon (LXe) detectors. Gamma rays from the decay of xenon metastable states, produced by fast neutron activation, were detected and their activities measured in a LXe scintillation detector. Following a five-day activation of natural xenon gas with a Cf (4× 10 n/s) source, the activities of two gamma ray lines at...

متن کامل

Electron Multiplication and Secondary Scintillation in Liquid Xenon: New Prospects

The history, present situation and prospects on electron multiplication and secondary scintillation in liquid xenon and their application to radiation detectors are shortly discussed.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010