The effect of proximal femur geometry, bone quality and stem shapes in the cemented total hip replacement

نویسندگان

  • Y-S Lai
  • H-W Wei
  • C-K Cheng
چکیده

Y-S Lai, H-W Wei and C-K Cheng 1 Institute of Biomedical Engineering, National Yang Ming University, Taipei, TAIWAN 2 Joint Prosthesis Technology Research Center, National Yang Ming University, Taipei, TAIWAN INTRODUCTION Aseptic loosening of the component is an important long-term complication of total hip arthroplasty. Kobayashi et al. found that the factor which affecting aseptic loosening of femoral stem after THRs was affected by an unfavorable geometry of the medullary canal (a so-called stovepipe canal or a large canal). The shape of the femoral canal has high individual difference which is much more variable than most femoral prosthesis would suggest or can accommodate. Furthermore, Noble et al. found that only the female femora displayed significant differences in canal shape or endosteal width as a function of age. Krischak et al. found that femoral prosthesis loosening can be predicted by the mechanical bone quality of the femoral head at the time of implantation. Those studies considered that the femoral canal shape or bone quality may affect the result after THRs. The goal of this study was to evaluate the influences and relationship of proximal canal shape, bone quality and stem flare (shapes) after total hip replacement by finite element analysis. METHODS Four two-dimensional finite element models (Figure 1a) were constructed in this study. We used NLF as the symbol for the normal canal femur (N) implanted with low flare (LF) stem, NHF as the symbol for the normal canal femur implanted with high flare (HF) stem, SLF as the symbol for the stovepipe canal femur (S) model implanted with low flare stem, and SHF as the symbol for the normal canal femur implanted with high flare stem. We defined the ratio of the cross-section width of proximal and distal stem as stem flare index (SFI), where the ratio greater than 3 was defined as HF stem and less was LF stem (Figure 1b). All materials were assumed to be isotropic, linearly elastic and homogeneous. In order to evaluate the effect of bone quality in THR, ten elastic modulus values of cancellous bone from 80 to 800 MPa were adopted. The boundary conditions of the models were showed in Figure 1b. RESULTS AND DISCUSSION The results in each model were as shown in Figure 2 and Figure 3. The results included the maximum principal stress in the cement and the average von Mises stress at the calcar region of cortical bone. In our results of the SLF model, high principal stress was occurred at stem/cement interface near the stem tip compared with NLF model, whether the bone quality was normal or poor. These results could explain the clinical results of Kobayashi and showed the cement failure at the stem distal was the main factor which would cause the stem loosening after THR. Moreover, the values of the tensile stresses were sensitive to the poor bone quality (the modulus of bone lower than 400 MPa). Surgeons need to concern about the high potential of stem loosening in the old female patients who had poor bone quality or stovepipe canal shape; and a newer design of hip stem for the old female patients should be consider. Several studies have reported that a reduction in the diameter of the distal stem while increasing the cement mantle thickness reduced the maximum principal stress of cement. In present study, the stresses in the cement layer of the NHF and SHF models were decreased obviously as compared with the NLF and SLF models, respectively. However, the high stresses which occurred in the distal end of cement in the NLF or SLF model were transferred to the lateral-middle as the stem change to high flare stem. Overall, the low flare stem seems to be the better one to adopt in the stovepipe canal femur. In this study, the modulus of bone lower than 400 MPa showed the high stress shielding effect at the calcar region. The stresses would concentrate in the distal region of cement layer because the poor bone quality can’t resist the loading and caused the large deformation of cement. Those results also explained why a stovepipe canal limited the durability of the hip prosthesis. Furthermore, we found the high flare stem increased the stress shielding effect at the calcar region compared with the low flare stem in this study. The reason could be the high stiffness at the proximal of the high flare stem which led to more stress shielding effect. CONCLUSIONS We concluded that the poor bone quality has a higher influence on the cement failure and stress shielding effect than femoral canal shapes and stem shapes. The stem flare (high or low flare design) seems not the main factor which could decrease the cement failure or stress shielding effect effectively. REFERENCES 1. Anthony PP et al. J Bone Joint Surg [Br] 72:971, 1990 2. Hedia HS et al. Biomed Mater Eng 6:135, 1996 3. Kobayashi S et al. J Bone Joint Surg [Am] 79:1618, 1997 4. Krischak GD et al. Clin Biomech 18(10):916-23, 2003. 5. Noble PC et al. Clin Orthop 316:31, 1995

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bone density study of the proximal femur after hip arthroplasty with porous-coated implants

Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...

متن کامل

Hip Arthroplasty and its Revision in a Child: Case Report and Literature Review

Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...

متن کامل

Influence of stem geometry on the stability of polished tapered cemented femoral stems.

Polished, tapered stems are now widely used for cemented total hip replacement and many such designs have been introduced. However, a change in stem geometry may have a profound influence on stability. Stems with a wide, rectangular proximal section may be more stable than those which are narrower proximally. We examined the influence of proximal geometry on stability by comparing the two-year ...

متن کامل

Total Hip Arthroplasty Using a Polished Tapered Cemented Stem in Hereditary Multiple Exostosis

A 61-year-old Japanese man underwent right total hip arthroplasty for hereditary multiple exostosis. At first presentation, he had suffered from coxalgia for a long time. On radiographic images, there was a gigantic femoral head, increased shaft angle, and large diameter of the femoral neck. He had also developed coxarthrosis and severe pain of the hip joint. The transformation of the proximal ...

متن کامل

Effects of Hip Geometry on Fracture Patterns of Proximal Femur

  Background: Some studies have previously shown that geometry of proximal femur can affect the probability of fracture and type of fracture. It happens since the geometry of the proximal femur determines how a force is applied to its different parts. In this study, we have compared proximal femur’s geometric characteristics in femoral neck (FNF), intertrochanteric (ITF) and Subtrochanteric (ST...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007