International Journal of Pharma and Bio Sciences V1(2)2010 DEVELOPMENT AND VALIDATION OF SPECTROPHOTOMETRIC AND RP-HPLC METHOD FOR ESTIMATION OF OLMESARTAN MEDOXOMIL IN TABLET DOSAGE FORM

نویسندگان

  • Prabhat Jain
  • Anurekha Jain
  • Deepika Maliwal
  • Vaibhav Jain
چکیده

Two simple and sensitive spectrophotometric and RP-HPLC methods are described for the determination of Olmesartan Medoxomil. The first method Spectrophotometry was based on the standard curve. Olmesartan Medoxomil exhibits λmax at 258 nm. Quantitative estimation of Olmesartan Medoxomil was carried out the standard calibration curve at 258 nm. The second method, high-performance liquid chromatographic method was developed for the determination of Olmesartan Medoxomil using Acetonitrile: Methanol (50:50, v/v) and pH adjust 4.0 with glacial acetic acid as the mobile phase and measuring the response at λmax 256 nm. The analysis was performed on a Lichrocart C18 (250 X 4.0 mm), 5-μm column. The method was found to be accurate, with linearity ranging from 2 to24 for spectrophotometry and 5 to30 for HPLC with a correlation coefficient (r2) 0.9994 and 0.9996 respectively. Precision mean % assay was found to be 99.09 for spectrophotometry and 99.53 for HPLC, The mean % recovery was found to be 99.5 -107.01 for spectrophotometry and 100.6-106.9 for HPLC

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and Validation of RP-HPLC Method for the Determination of Methamphetamine and Propranolol in Tablet Dosage Form

A new isocratic reversed-phase HPLC method with diode-array UV detection was developed and validated for the determination of methamphetamine and propranolol in tablet dosage forms. Chromatography was carried out on an XTerra RP18 (150×4.6 mm, 5 μm) column using 50 mM pyrrolidine (pH 11.5) - acetonitrile (50:50, v/v) as mobile phase at a flow rate of 1 ml/min. Spectrophotometric detection was p...

متن کامل

Method Development and Validation for Simultaneous Estimation of Olmesartan Medoxomil and Hydrochlorothiazide by RP-HPLC SURYADEVARA VIDYADHARA*, REDDYVALAM LANkAPALLI CH SASIDHAR, BALLIPALLI VENkATESwARA RAO, kODURI TEJASwI and MARUPUDI RESHMA

A simple, fast, precise reverse phase isocratic high performance liquid chromatographic (HPLC) method has been developed for the simultaneous estimation of Olmesartan medoxomil (OM) and hydrochlorothiazide (HCTZ) in marketed formulations. Estimation of drugs in this combination was done with a C18 column [ODS UG 5 column, 250mm x 4.5mm] using mobile phase of composition acetonitrile and phospha...

متن کامل

Development and Validation of Rp-hplc and Spectrophotometric Method for Simultaneous Estimation of Atorvastatin and Amlodipine in Pharmaceutical Dosage Forms

A simple, rapid, precise, accurate, sensitive and time consuming reverse phase high performance liquid chromatography (RP-HPLC) and spectrophotometric method for simultaneous estimation of atorvastatin and amlodipine in pharmaceutical dosage forms have been developed and validated. Drug was resolved on a C18 column (Phenomenex phenyl hexyl column, 250mm* 4.6mm i.d, 5um). Utilizing mobile phase ...

متن کامل

Analytical method development and validation of Tolterodine in pharmaceutical dosage forms by RP-HPLC

A new sensitive, simple, rapid and precise reversed phase high performance liquid chromatographic (HPLC) and a spectrophotometric method has been developed for estimation of tolterodine in tablet dosage form. Chromatography was performed by using the mobile phase, Potassium Phosphate pH 4.5 and acetonitrile mixed by a low pressure gradient program. Hypersil BDS C18 column was used. The waveleng...

متن کامل

Development and Validation of an Uv Spectrophotometric Method for the Determination of Aliskiren in Tablets

For determination of aliskiren in commercial samples, an analytical UV spectrophotometric method was developed and validate according to ICH guideline. The method was linear in the range between 40 and 100 μg mL (r = 0.9997, n = 7) and exhibited suitable specificity, accuracy, precision, and robustness. It is simple, it has low cost, and it has low use polluting reagents. Therefore, the propose...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010