Arterial line pressure control enhanced extracorporeal blood flow prescription in hemodialysis patients

نویسندگان

  • Franklin G Mora-Bravo
  • Alfonso Mariscal
  • Juan P Herrera–Felix
  • Salvador Magaña
  • Guadalupe De-La-Cruz
  • Nelly Flores
  • Laura Rosales
  • Martha Franco
  • Héctor Pérez-Grovas
چکیده

BACKGROUND In hemodialysis, extracorporeal blood flow (Qb) recommendation is 300-500 mL/min. To achieve the best Qb, we based our prescription on dynamic arterial line pressure (DALP). METHODS This prospective study included 72 patients with catheter Group 1 (G1), 1877 treatments and 35 arterio-venous (AV) fistulae Group 2 (G2), 1868 treatments. The dialysis staff was trained to prescribe Qb sufficient to obtain DALP between -200 to -250 mmHg. We measured ionic clearance (IK: mL/min), access recirculation, DALP (mmHg) and Qb (mL/min). Six prescription zones were identified: from an optimal A zone (Qb > 400, DALP -200 to -250) to zones with lower Qb E (Qb < 300, DALP -200 to -250) and F (Qb < 300, DALP > -199). RESULTS Treatments distribution in A was 695 (37%) in G1 vs. 704 (37.7%) in G2 (P = 0.7). In B 150 (8%) in G1 vs. 458 (24.5%) in G2 (P < 0.0001). Recirculation in A was 10.0% (Inter quartile rank, IQR 6.5, 14.2) in G1 vs. 9.8% (IQR 7.5, 14.1) in G2 (P = 0.62). IK in A was 214 +/- 34 (G1) vs. 213 +/- 35 (G2) (P = 0.65). IK Anova between G2 zones was: A vs. C and D (P < 0.000001). Staff prescription adherence was 81.3% (G1) vs. 84.1% (G2) (P = 0.02). CONCLUSION In conclusion, an optimal Qb can de prescribed with DALP of -200 mmHg. Staff adherence to DLAP treatment prescription could be reached up to 81.3% in catheters and 84.1% in AV fistulae.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of controlled extracorporeal blood cooling on ultrafiltration-induced blood volume changes during hemodialysis.

Considerable amounts of heat may be lost or gained through the extracorporeal circuit during hemodialysis and influence the hemodynamic stability of the dialysis patient. The effects of two levels of extracorporeal heat flux (Jtherm in W) on blood pressures and ultrafiltration-induced blood volume changes were studied in eight patients on conventional hemodialysis. Treatments were controlled au...

متن کامل

Comparing the Effect of Simple Filtration Hemodialysis and Ultrafiltration Hemodialysis on Arterial Oxygen Saturation and Blood Pressure in Chronic Dialysis

Background and purpose: Hypoxemia and hypotension are important complications of hemodialysis in patients with chronic renal failure that are linked to several factors, including the type of filters used. The aim of this study was to compare the effect of simple filtration hemodialysis and ultrafiltration hemodialysis on blood pressure and blood arterial oxygen level. Materials and methods: In...

متن کامل

Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall

Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been  introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the  substitution  of  the  blood  pressure  changes  in  the  central  arteries  such  as  carotid  with  the  blood  pressure  changes in the brachial results in error in the blood...

متن کامل

Exceptional Cases More may be less: increasing extracorporeal blood flow in an axillary arterio-arterial access decreases effective clearance

Axillary arterio-arterial graft interposition has been described as a reasonable haemodialysis access in selected patients. In a patient with this unusual access, we measured and calculated effective clearance at different extracorporeal blood flows (Qb). Effective clearance increased with increasing blood flow and reached a maximum at a Qb of ∼200 mL/min but then decreased when Qb was increase...

متن کامل

Cerebral blood flow during cardiopulmonary bypass in man: effect of arterial filtration.

Cerebral blood flow was recorded in 39 patients undergoing cardiac surgery by intraarterial injection of xenon 133. There were three subgroups of patients: 10 patients had a 20 micron arterial filter (Johnson) and 11 a 40 micron filter (Pall), and 18 had no arterial filtration. All patients had a 40 micron (Pall) filter in the coronary suction line. Significant changes in cerebral blood flow oc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Nephrology

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2008