Analytical Investigations of Toxic p-Phenylenediamine (PPD) Levels in Clinical Urine Samples with Special Focus on MALDI-MS/MS
نویسندگان
چکیده
Para-phenylenediamine (PPD) is a common chromophoric ingredient in oxidative hair-dyes. In some African countries like Sudan, Egypt and Morocco but also in India this chemical is used alone or in combination with colouring extracts like Henna for dyeing of the hair or the skin. Excessive dermal exposure to PPD mainly leads to the N-mono- and N,N'-diacetylated products (MAPPD, DAPPD) by N-acetyltransferase 1 and 2 (NAT1 and 2) catalyzed reactions. Metabolites and PPD are mainly excreted via renal clearance. Despite a low risk of intoxication when used in due form, there are numerous cases of acute intoxication in those countries every year. At the ENT Hospital - Khartoum (Sudan) alone more than 300 cases are reported every year (~10% fatal), mostly caused by either an accidental or intended (suicidal) high systemic exposure to pure PPD. Intoxication leads to a severe clinical syndrome including laryngeal edema, rhabdomyolysis and subsequent renal failure, neurotoxicity and acute toxic hepatitis. To date, there is no defined clinical treatment or antidote available and treatment is largely supportive. Herein, we show the development of a quick on-site identification assay to facilitate differential diagnosis in the clinic and, more importantly, the implementation of an advanced analytical platform for future in-depth investigations of PPD intoxication and metabolism is described. The current work shows a sensitive (~25 µM) wet chemistry assay, a validated MALDI-MS/MS and HPLC-UV assay for the determination of PPD and its metabolites in human urine. We show the feasibility of the methods for measuring PPD over a range of 50-1000 µM. The validation criteria included linearity, lower limit of quantification (LLOQ), accuracy and precision, recovery and stability. Finally, PPD concentrations were determined in clinical urine samples of cases of acute intoxication and the applied technique was expanded to identify MAPPD and DAPPD in the identical samples.
منابع مشابه
Direct identification of urinary tract pathogens from urine samples by matrix-assisted laser desorption ionization-time of flight mass spectrometry.
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been suggested as a reliable method for bacterial identification from cultures. Direct analysis of clinical samples might increase the usefulness of this method, shortening the time for microorganism identification. We compared conventional methods for the diagnosis of urinary tract infections (UTIs)...
متن کاملMALDI-TOF MS for the diagnosis of infectious diseases.
BACKGROUND First introduced into clinical microbiology laboratories in Europe, MALDI-TOF MS is being rapidly embraced by laboratories around the globe. Although it has multiple applications, its widespread adoption in clinical microbiology relates to its use as an inexpensive, easy, fast, and accurate method for identification of grown bacteria and fungi based on automated analysis of the mass ...
متن کاملGram-Stain Plus MALDI-TOF MS (Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry) for a Rapid Diagnosis of Urinary Tract Infection
Microbiological confirmation of a urinary tract infection (UTI) takes 24-48 h. In the meantime, patients are usually given empirical antibiotics, sometimes inappropriately. We assessed the feasibility of sequentially performing a Gram stain and MALDI-TOF MS mass spectrometry (MS) on urine samples to anticipate clinically useful information. In May-June 2012, we randomly selected 1000 urine samp...
متن کاملDual Modifications Strategy to Quantify Neutral and Sialylated N-Glycans Simultaneously by MALDI-MS
Differences in ionization efficiency among neutral and sialylated glycans prevent direct quantitative comparison by their respective mass spectrometric signals. To overcome this challenge, we developed an integrated chemical strategy, Dual Reactions for Analytical Glycomics (DRAG), to quantitatively compare neutral and sialylated glycans simultaneously by MALDI-MS. Initially, two glycan samples...
متن کاملDevelopment of a UPLC-ESI-MS/MS assay for 20(S)-protopanaxadiol and pharmacokinetic application of its two formulations in rats.
An ultra-performance liquid chromatography-electrospray tandem mass spectrometry (UPLC-ESI-MS/MS) method was developed to investigate 20(S)-protopanaxadiol (PPD) pharmacokinetics in rats. Rat plasma samples were treated using a solid-phase extraction with satisfactory recovery (> 81%). The method showed an excellent sensitivity that the limit of detection (LOD) and the lower limit of quantitati...
متن کامل