Quenching-Chemiluminescence Determination of Trace Amounts of l-Tyrosine Contained in Dietary Supplement by Chemiluminescence Reaction of an Iron-Phthalocyanine Complex
نویسندگان
چکیده
The chemiluminescence (CL) signal immediately appeared when a hydrogen peroxide solution was injected into an iron-phthalocyanine tetrasulfonic acid (Fe-PTS) aqueous solution. Moreover, the CL intensity of Fe-PTS decreased by adding l-tyrosine. Based on these results, the determination of trace amounts of l-tyrosine was developed using the quenching-chemiluminescence. The calibration curve of l-tyrosine was obtained in the concentration range of 2.0 × 10(-7) M to 2.0 × 10(-5) M. Moreover, the relative standard deviation (RSD) was 1.63 % (n = 5) for 2.0 × 10(-6) M l-tyrosine, and its detection limits (3σ) were 1.81 × 10(-7) M. The spike and recovery experiments for l-tyrosine were performed using a soft drink. Furthermore, the determination of l-tyrosine was applied to supplements containing various kinds of amino acids. Each satisfactory relative recovery was obtained at 98 to 102%.
منابع مشابه
Chemiluminescence Reaction of an Iron(III)-Phthalocyanine Complex and Its Application to FIA of L-Tyrosine
Chemiluminescence (CL) of a metal–phthalocyanine complex was studied, and an analytical application of CL detection-flow injection analysis (FIA) of L-tyrosine was developed. The CL reaction of iron (III)–phthalocyanine tetrasulfonic acid (Fe–PTS) was examined using eight metals (Cu, Fe, Ni, Co, Mg, Pd, Pt and Zn)–phthalocyanine complexes. The CL signal immediately appeared, when the Fe-PTS aqu...
متن کاملChemiluminescence Determination of Atropine using Luminol-Hemin-H2O2 System
A sensitive and fast chemiluminescence (CL) method has been described for the direct determination of atropine. The method is based on the quenching effect of atropine on the CL signals of the luminol– H2O2 reaction catalyzed by hemin in an alkaline medium. Hemin could strongly enhance the chemiluminescence of the luminol–H2O2 system. The luminophor of the luminol–H2O2–hemin CL system was ident...
متن کاملTerbium Sensitized Chemiluminescence Method for the Determination of Rabeprazole -Application to Pharmaceutical Analysis and Dissolution Studies
A simple and sensitive chemiluminescence-based method was established for the determination of rabeprazole.The proposed method was based on the enhancing effect of rabeprazole on Ce(IV)-Na2SO3 -Tb(III) chemiluminescence reaction. A possible mechanism was discussed for chemiluminescence system by studying UV-Vis, fluorescence and chemiluminescence spectra. The effects of va...
متن کامل[Sensitive determination of reactive oxygen species by chemiluminescence methods and their application to biological samples and health foods].
Sensitive and selective methods, based on chemiluminescence reactions, were introduced for determination of reactive oxygen species (ROS) and their applications to biological samples and health foods. First, a sensitive method for determination of H(2)O(2) by peroxyoxalate chemiluminescence (PO-CL) was developed. This method could be applied to determine small amounts of H(2)O(2) in cola drinks...
متن کاملChemiluminescence Determination of Hydroxyzine and its Metabolite Cetirizine
A chemiluminescence (CL) method has been developed for the determination of Hydroxyzine (Hyd) and its metabolite Cetirizine (Cet). The method is based on sensitizing effect of Cet and Hyd on the weak CL reaction between Ru(phen)32+ and acidic Ce(IV). A mechanism for the CL reaction has been proposed on the basis of UV-Vis, fluorescent and CL spectra. By using the recommended procedure, the cali...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2012 شماره
صفحات -
تاریخ انتشار 2012