Determining optimal two-beam axial orientations for heart sparing in left-sided breast cancer patients.
نویسندگان
چکیده
BACKGROUND AND PURPOSE The optimal intensity fluence profile of a beam depends on the profiles of other beams but most optimizations assume fixed beam orientations, a priori. Breast cancer radiotherapy attempts to cover the target and to spare critical structures such as the heart and lungs. The study aims are (1) to determine and document the optimal two-beam orientation that best spares the heart for left-sided breast cancer patients and (2) to investigate the influence of the treatment technique (i.e., conformal versus intensity modulation) on the optimal objective cost function. MATERIAL AND METHODS Ten left-sided breast cancer patients were planned using a conformal (3DCRT) and a simplified intensity modulated (sIMRT) technique using predefined segments and different two-beam orientations. Optimal segment weights were determined exhaustively for all axial two-beam combinations, in 5 degree increments, by minimizing a quadratic objective cost function. The resulting objective cost function was analyzed with respect to target geometry and treatment technique. RESULTS The sIMRT plans are generally less sensitive to beam orientation compared to 3DCRT plans. Optimal two-beam orientations for 3DCRT and sIMRT plans exist and they correspond to a hinge angle of approximately 188 degrees and 160 degrees or 210 degrees (the latter is bimodal), respectively. CONCLUSIONS The optimization software is a useful tool that can test many different beam combinations and estimate their associated objective cost values. Afterwards, the most promising beam orientations could be re-optimized under the TPS to fine-tune and verify the dose distributions. Optimal uniform two-beam orientations for the breast consist of opposing tangential medial and lateral beams. Optimal nonuniform two-beam orientations for left-sided breast cancers are bimodal, containing hinge angles around 160 degrees and 210 degrees. Nonuniform beam techniques are less sensitive to beam orientation compared to uniform beam techniques and result in significantly improved heart sparing but at a cost of slightly compromised planning target volume coverage.
منابع مشابه
Intensity modulated radiation therapy (IMRT) technique for left breast cancer by different numbers of beam fields
Background: Intensity Modulated Radiotherapy (IMRT) can improve radiotherapy (RT) results by improving healthy tissue sparing. Additionally, IMRT provides more consistent dose deliveries and suppresses secondary tumor formation. RT is a principal treatment in breast cancer (BC). Aim: To evaluate the outcome of the Radiotherapy Plans (RTP) that use IMRT technique to left breast and other organs,...
متن کاملSimplified intensity-modulated radiotherapy using pre-defined segments to reduce cardiac complications in left-sided breast cancer.
BACKGROUND AND PURPOSE Left-sided breast cancer patients pose a difficult clinical challenge when significant heart and contralateral breast irradiation are present, particularly with tangential uniform beams. The aims of the study are: (1) to design and evaluate a simplified intensity-modulated radiotherapy (IMRT) (SI) solution using pre-defined segments, (2) to compare the SI technique with a...
متن کاملRadiation-induced myocardial perfusion abnormalities in breast cancer patients following external beam radiation therapy
Objective(s): Radiation therapy for breast cancer can induce myocardial capillary injury and increase cardiovascular morbidity and mortality. A prospective cohort was conducted to study the prevalence of myocardial perfusion abnormalities following radiation therapy of left-sided breast cancer patients as compared to those with right–sided cancer. Methods: To minimize potential confounding fact...
متن کاملDose-volume Analysis of Heart and Lung during 3D Planning of Tangential Breast Cancer Irradiation
Introduction: Breast cancer is becoming more frequently diagnosed at early stages with improved long-term outcomes. Radiation-related heart disease and lung cancer can occur following radiotherapy for breast cancer. The aim of this study was to evaluate some dosimetric parameters of heart and lung during whole breast radiotherapy. Materials and Methods: Twenty...
متن کاملA Comparative Study of 3-D Conformal Radiotherapy Treatment Plans with and Without Deep Inspiration Breath-Hold Technique for Left-Sided Breast Cancer
Introduction: The rate of cardiac diseases have increased among patients who underwent radiotherapy for left-sided breast cancer. The study’s aim was evaluate the dose to organs at risk in free-breathing 3-dimensional conformal (FB-3DCRT) against 3-dimensional conformal deep inspiration breath-hold (3DCRT-DIBH) in patients with left-sided breast cancer. Ma...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 31 1 شماره
صفحات -
تاریخ انتشار 2004