Central Venous Pressure as a Predictor of Fluid Responsiveness: Is This All You Need?
نویسندگان
چکیده
Fluid administration during and after surgery is a fundamental strategy for maintaining hemodynamic stability. Technology offers different strategies for hemodynamic monitoring and decision making about fluids administration. In particular patients may be divided into fluid-responding patients and non-fluid-responding patients. Central venous pressure, measured by a central venous catheter, is a basic measure of right heart preload, and many trials defined it as a non-trustable parameter, with many biases and confounding factors, such as mechanical ventilation and intrathoracic pressure. Nevertheless, many authors describe how a simple value like the Central venous pressure may be useful in hemodynamic monitoring during and after cardiac surgery, although it is not the best available. Moreover the results of a recent survey performed in cardiothoracic intensive care units in Italy, reported how central venous pressure was the easiest and the most frequently used parameter for the monitoring of fluid therapy. Given this state of the art, Central venous pressure seems to be the most criticized but, due to its feasibility and availability, it is still the most used parameter for the evaluation of preload and for the prediction of fluid responsiveness in operating room and Intensive Care Unit.
منابع مشابه
Is the pulse pressure variation a good predictor of fluid responsiveness in mechanically ventilated patients with low tidal volume?
A transversal and interventional study that included 30 critically ill patients with acute circulatory failure, sedated and mechanically ventilated with a tidal volume of 6 to 7 ml/kg. Mechanical ventilatory measurements including positive end-expiratory pressure plateau and peak pressures, static compliance and hemodynamic measurements including PPV, heart rate, mean systemic and pulmonary art...
متن کاملHigh mixed venous oxygen saturation levels do not exclude fluid responsiveness in critically ill septic patients
INTRODUCTION The aim of this study was to determine whether the degree of fluid responsiveness in critically ill septic patients is related to baseline mixed venous oxygen saturation (SvO2) levels. We also sought to define whether fluid responsiveness would be less likely in the presence of a high SvO2 (>70%). METHODS This observational study was conducted in a 32-bed university hospital medi...
متن کاملبررسی ارزش تشخیصی میزانCaval index در تعیین فشار ورید مرکزی پایین در مقایسه با روش تهاجمی در بیماران بستری در ICU بیمارستان شهید باهنر کرمان
Introduction: Measurement of central venous pressure can be regarded as a beneficial guide in order to assess a patient's hemodynamic status, specifically in patient with sever sepsis and septic shock, for whom a central venous pressure of less than 8mmhg is considered as an indicator for aggressive intravenous fluid replacement. Therefore, this study aimed to investigate the ultrasonographic e...
متن کاملRespiratory variation in inferior vena cava diameter: surrogate of central venous pressure or parameter of fluid responsiveness? Let the physiology reply
In the previous issue of Critical Care, Muller and colleagues investigated whether respiratory variation in inferior vena cava diameter (ΔIVC) could be a useful predictor of fluid responsiveness in spontaneously breathing patients. The study concludes that accuracy was not very good and therefore that this parameter should be used with caution in these patients. There is still confusion about t...
متن کاملPredicting the Need for Fluid Therapy—Does Fluid Responsiveness Work?
Fluid overdose can be harmful in critically ill patients. Since central venous pressure (CVP) is currently considered to be an inappropriate indicator of preload, much attention is being given to predicting fluid responsiveness, i.e., the response of stroke volume (SV) or cardiac output (CO) to fluid challenge. However, when fluid responsiveness was evaluated in critically ill patients, includi...