Monitoring with head-mounted displays: performance and safety in a full-scale simulator and part-task trainer.
نویسندگان
چکیده
BACKGROUND Head-mounted displays (HMDs) can help anesthesiologists with intraoperative monitoring by keeping patients' vital signs within view at all times, even while the anesthesiologist is busy performing procedures or unable to see the monitor. The anesthesia literature suggests that there are advantages of HMD use, but research into head-up displays in the cockpit suggests that HMDs may exacerbate inattentional blindness (a tendency for users to miss unexpected but salient events in the field of view) and may introduce perceptual issues relating to focal depth. We investigated these issues in two simulator-based experiments. METHODS Experiment 1 investigated whether wearing a HMD would affect how quickly anesthesiologists detect events, and whether the focus setting of the HMD (near or far) makes any difference. Twelve anesthesiologists provided anesthesia in three naturalistic scenarios within a simulated operating theater environment. There were 24 different events that occurred either on the patient monitor or in the operating room. Experiment 2 investigated whether anesthesiologists physically constrained by performing a procedure would detect patient-related events faster with a HMD than without. Twelve anesthesiologists performed a complex simulated clinical task on a part-task endoscopic dexterity trainer while monitoring the simulated patient's vital signs. All participants experienced four different events within each of two scenarios. RESULTS Experiment 1 showed that neither wearing the HMD nor adjusting the focus setting reduced participants' ability to detect events (the number of events detected and time to detect events). In general, participants spent more time looking toward the patient and less time toward the anesthesia machine when they wore the HMD than when they used standard monitoring alone. Participants reported that they preferred the near focus setting. Experiment 2 showed that participants detected two of four events faster with the HMD, but one event more slowly with the HMD. Participants turned to look toward the anesthesia machine significantly less often when using the HMD. When using the HMD, participants reported that they were less busy, monitoring was easier, and they believed they were faster at detecting abnormal changes. CONCLUSIONS The HMD helped anesthesiologists detect events when physically constrained, but not when physically unconstrained. Although there was no conclusive evidence of worsened inattentional blindness, found in aviation, the perceptual properties of the HMD display appear to influence whether events are detected. Anesthesiologists wearing HMDs should self-adjust the focus to minimize eyestrain and should be aware that some changes may not attract their attention. Future areas of research include developing principles for the design of HMDs, evaluating other types of HMDs, and evaluating the HMD in clinical contexts.
منابع مشابه
Advanced auditory displays and head-mounted displays: advantages and disadvantages for monitoring by the distracted anesthesiologist.
BACKGROUND In a full-scale anesthesia simulator study we examined the relative effectiveness of advanced auditory displays for respiratory and blood pressure monitoring and of head-mounted displays (HMDs) as supplements to standard intraoperative monitoring. METHODS Participants were 16 residents and attendings. While performing a reading-based distractor task, participants supervised the act...
متن کاملDriving and Side Task Performance: The Effects of Display Clutter, Separation, and Modality
In-vehicle technologies (IVTs) create additional tasks for the driver. To the extent that these devices degrade driving performance, there will be safety concerns. This study examines the effects of display clutter from overlay, display separation, and modality on driving and IVT task performance. In a fixed-base simulator, 22 drivers drove different routes and responded to infrequent, unexpect...
متن کاملAssessing Simulator Sickness in a See-through Hmd: Effects of Time Delay, Time on Task, and Task Complexity
Advances in helmet-mounted displays (HMDs) have permitted the design of “see-through” displays in which virtual imagery may be superimposed upon real visual environments. Such displays have numerous potential applications; however, their promise to improve human perception and performance in complex task environments is threatened by numerous technological challenges. Moreover, users of HMDs ma...
متن کاملA Station with Multiple Head-Mounted Displays for Learning Advanced Driver Assistance Systems
Advanced driver assistance systems (ADAS) are technologies that provide drivers with essential information or take over difficult and repetitive tasks. They contribute to improving road safety and increasing driving comfort. Apart from the technical development challenges, training and demonstration of ADAS in safe environments are important concerns for automobile manufacturers and suppliers. ...
متن کاملHead-slaved Tracking in a See-through Hmd: the Effects of a Secondary Visual Monitoring Task on Performance and Workload
Technological advances in helmet-mounted displays (HMDs) have permitted the design of “see-through” displays in which virtual imagery may be superimposed upon real visual environments. The utility of see-through displays in multitask environments remains uncertain, especially in environments that involve switching one’s attention between those tasks represented in the virtual display and those ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesia and analgesia
دوره 109 4 شماره
صفحات -
تاریخ انتشار 2009