Ventriculoatrial conduction metrics for classification of ventricular tachycardia with 1:1 retrograde conduction in dual-chamber sensing implantable cardioverter defibrillators.
نویسندگان
چکیده
The introduction of dual-chamber sensing in implantable cardioverter defibrillators (ICDs) has greatly reduced the incidence of false detection due to supraventricular tachycardias. The remaining arrhythmias which serve to confound classification are supraventricular tachycardias (SVTs) with 1:1 anterograde conduction and ventricular tachycardias (VT) with 1:1 retrograde conduction. An algorithm has been designed and tested (28 patients) which employs ventriculoatrial (VA) conduction measurements to separate 1:1 VTs from 1:1 SVTs. A study was conducted to assess realistic VA interval boundaries for classification of arrhythmias with 1:1 retrograde atrial conduction. Intracardiac atrial and ventricular recordings of 7 passages of VT with retrograde conduction, 12 passages of atrioventricular nodal reentrant tachycardia (AVNRT), 3 passages of atrial tachycardia (AT), 8 passages of sinus tachycardia (ST), and 2 passages of orthodromic reentrant tachycardia (ORT) were analyzed. Automated real-time atrial and ventricular waveform recognition was performed on each passage and VA intervals were measured. Separation of VT with retrograde conduction from other 1:1 supraventricular tachycardias was effected by imposing discrete VA interval boundaries. VA boundaries of 80 ms to 234 ms classified 1:1 VT with 100% sensitivity (SENS) and 80% specificity (SPEC). In addition, the lower boundary completely classified AVNRT with 100% SENS and 100% SPEC, and all passages of ST were contained above the upper boundary. These findings could be of importance in algorithms for next-generation implantable cardioverter defibrillators which include two-chamber (atrial and ventricular) sensing and two-chamber interval measurements.
منابع مشابه
Atrial Sensing and Blanking in Dual-Chamber Implantable Cardioverter-Defibrillators
Atrial Sensing and Blanking in Dual-Chamber Implantable Cardioverter-Defibrillators Accurate atrial sensing during tachycardia is essential for reliable determination of atrial rate, which is a critical component of interval-based dual-chamber supraventricular tachycardia (SVT)–VT discrimination algorithms. Thus, atrial sensing in dual-chamber implantable cardioverter-defibrillators (ICDs) must...
متن کاملInitiation of ventricular tachycardia by interruption of pacemaker-mediated tachycardia in a patient with a dual-chamber implantable cardioverter defibrillator.
A 74-year-old man with a dual-chamber implantable cardioverter defibrillator implanted 3 years before experienced multiple ventricular tachycardias (VTs). All episodes were initiated by pacemaker-mediated tachycardia (PMT) that was either stopped by atrial undersensing or the tachycardia termination algorithm of the device. After the termination of PMT, two rapid ventricular paced beats, the fi...
متن کاملRepetitive Nonreentrant Ventriculoatrial Synchrony (RNRVAS)
Retrograde ventriculoatrial conduction in persons with implanted dual chamber pacemakers can cause two types of responses. One is the familiar pacemaker mediated endless loop tachycardia. Another less known response is the repititive non-rentrant ventriculoatrial synchrony (RNRVAS). Both conditions produce similar symptoms due to the loss of atrial booster function and the presence of the rever...
متن کاملSelective atrial sensing in dual chamber pacemakers eliminates endless loop tachycardia.
With the introduction of dual chamber pacemakers that have multiple atrial amplitude sensing values, selective P wave sensing is possible. Five consecutive patients were studied who had 1) retrograde atrioventricular conduction, 2) anterograde atrial signals that were at least 1.4 times larger than their corresponding retrograde atrial signals, and 3) dual chamber pulse generators that are capa...
متن کاملA diagnostic pitfall in a patient with an implantable cardioverter-defibrillator.
Apatient with dilated cardiomyopathy and aborted sudden death was admitted for repeated shocks from his Guidant Ventak Prizm dual chamber implantable cardioverterdefibrillator (ICD). Interrogation of stored events over the last six months revealed 46 episodes at a rate of 140/min, interpreted as ventricular tachycardia (VT). These were usually interrupted by programmed overdrive ventricular pac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of electrocardiology
دوره 31 Suppl شماره
صفحات -
تاریخ انتشار 1998