Use of swabs without transport media for the Gen-Probe Group A Strep Direct Test.

نویسندگان

  • Paul P Bourbeau
  • Barbara J Heiter
چکیده

For several years we used rayon or Dacron swabs with liquid transport media for collection and transport of throat swab specimens for testing with the Gen-Probe Group A Strep Direct Test (GASDT). A report of favorable results with a Dacron swab without any transport media for GASDT by another laboratory prompted us to compare detection of group A streptococci (GAS) with and without transport media (referred to as "wet" and "dry" swabs, respectively). Phase one of this study used swabs seeded with GAS. Initially, six recent clinical isolates of GAS were inoculated onto wet and dry swabs and stored at room temperature (RT). After 1, 2, and 3 days of storage, colony counting and GASDT were performed with the swabs. The results, expressed as the mean percentage of the results at zero time, were as follows: for GASDT with wet swabs at 1, 2, and 3 days, 62, 51, and 56%, respectively; for GASDT with dry swabs at 1, 2, and 3 days, 105, 80, and 85%, respectively; for colony counts with wet swabs at 1, 2, and 3 days, 52, 26, and 13%, respectively; for colony counts with dry swabs at 1, 2, and 3 days, 10, 0, and 0%, respectively. An additional six strains of GAS were tested in a similar manner, except that extracts of pharyngeal flora (PF) were added to the inocula. The results obtained with extracts of PF were comparable to those obtained with GAS alone. We also compared the performance of GASDT with wet and dry swabs stored at RT and 4 degrees C. Ten strains of GAS were inoculated onto wet and dry swabs, and GASDT was performed each day for 9 days. The GASDT results for swabs on day 9, expressed as the mean percentage of the results obtained at zero time, were as follows: dry swab and 4 degrees C, 59%; wet swab and 4 degrees C, 31%; dry swab and RT, 33%; and wet swab and RT, 19%. In phase two of this study we conducted a clinical evaluation to determine whether the differences observed with seeded specimens would also be evident with patient specimens. We used a single dry Dacron swab paired with a single rayon Bacti-Swab with liquid Stuart transport medium for the clinical evaluation. Specimens were collected from 1,005 outpatients, plated onto a Strep Selective Agar plate, and then tested within 30 min by GASDT. If culture of GAS from the same swab is used to define a true-positive test result, the sensitivities and specificities were as follows: GASDT with wet swabs, 86.2 and 98.5%, respectively; GASDT with dry swabs, 90.7 and 98.1%, respectively. However, the use of culture as the "gold standard" may understate the actual performance characteristics of GASDT, particularly for the dry swabs. In conclusion, for GASDT the use of swabs without transport media may be preferable to the use of swabs with transport media.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Copan swabs with liquid transport media for use in the Gen-Probe Group A Strep Direct Test.

The Gen-Probe Group A Streptococcus Direct Test (GASDT), which detects the presence or absence of group A streptococci directly from pharyngeal specimens, utilizes a specific relative light unit (RLU) cutoff of 4,500 to differentiate between positive and negative test results. In response to a report by a manufacturer that the background RLU values for the Copan rayon swabs with liquid media we...

متن کامل

Comparison of Gen-Probe Group A streptococcus Direct Test with culture for diagnosing streptococcal pharyngitis.

The Group A Streptococcus Direct Test (GP-ST test; Gen-Probe, Inc., San Diego, Calif.) was compared with culture for the detection of Streptococcus pyogenes from throat swabs of 767 patients with pharyngitis. Swabs were tested by the GP-ST test after inoculating a 5% sheep blood agar (SBA) plate. SBA plates were incubated at 35 degrees C in room air for 72 h. SBA plates with no evidence of beta...

متن کامل

Recovering streptococci from the throat, a practical alternative to direct plating in remote tropical communities.

Throat swabs are regarded as the "gold standard" for diagnosing streptococcal pharyngitis and for surveillance research. Culturing throats in remote tropical settings is logistically difficult, and these settings are commonly burdened by high rates of streptococcal disease. The survival of streptococci on swabs may depend on whether they are of "throat" or "skin" type, as determined by emm patt...

متن کامل

The evaluation of SD Bioline Strep A rapid antigen test in acute pharyngitis in pediatric clinics.

BACKGROUND Acute pharyngitis is a very common respiratory tract infection. Rapid antigen tests (RATs) that detect group A streptococci (GAS) have an advantage over conventional throat culture in determining the cause of acute pharyngitis quickly. The efficiency of RAT should be good enough to be used in the laboratory or in the clinics. METHODS From October 2008 through February 2009, throat ...

متن کامل

Fifteen-Minute Detection of Streptococcus pyogenes in Throat Swabs by Use of a Commercially Available Point-of-Care PCR Assay.

Since 2002, our clinical microbiology laboratory has routinely performed Streptococcus pyogenes PCR on throat swabs using a previously described LightCycler assay which uses Roche analytespecific reagent (ASR) primers and fluorescence resonance energy transfer (FRET) probes (1). The complexity of the assay required performance in the laboratory. Recently, the United States Food and Drug Adminis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 42 7  شماره 

صفحات  -

تاریخ انتشار 2004