Aulogous fibrin sealant (Vivostat(®)) in the neurosurgical practice: Part II: Vertebro-spinal procedures.
نویسندگان
چکیده
BACKGROUND Epidural hematomas, cerebrospinal fluid fistula, and spinal infections are challenging postoperative complications following vertebro-spinal procedures. We report our preliminary results using autologous fibrin sealant as both fibrin glue and a hemostatic during these operations. METHODS Prospectively, between January 2013 and March 2015, 68 patients received an autologous fibrin sealant prepared with the Vivostat(®) system applied epidurally to provide hemostasis and to seal the dura. The surgical technique, time to bleeding control, and associated complications were recorded. RESULTS Spinal procedures were performed in 68 patients utilizing autologous fibrin glue/Vivostat(®) to provide rapid hemostasis and/or to seal the dura. Only 2 patients developed postoperative dural fistulas while none exhibited hemorrhages, allergic reactions, systemic complications, or infections. CONCLUSIONS In this preliminary study, the application of autologous fibrin sealant with Vivostat(®) resulted in rapid hemostasis and/or acted as an effective dural sealant. Although this product appears to be safe and effective, further investigations are warranted.
منابع مشابه
Autologous fibrin sealant (Vivostat®) in the neurosurgical practice: Part I: Intracranial surgical procedure
BACKGROUND Hemorrhages, cerebrospinal fluid (CSF) fistula and infections are the most challenging postoperative complications in Neurosurgery. In this study, we report our preliminary results using a fully autologous fibrin sealant agent, the Vivostat(®) system, in achieving hemostasis and CSF leakage repair during cranio-cerebral procedures. METHODS From January 2012 to March 2014, 77 patien...
متن کاملPrevention of air leakage by spraying vivostat fibrin sealant after lung resection in pigs.
STUDY OBJECTIVES To evaluate Vivostat fibrin sealant in the prevention of air leakage after experimental lung resection in pigs. DESIGN Randomized study. SETTING University laboratory. METHODS Six Landrace pigs were operated on in both lungs through a median sternotomy. Five different resection sites were created in each lung. INTERVENTION Randomization was performed to either applicati...
متن کاملUse of Tisseel fibrin sealant in neurosurgical procedures: incidence of cerebrospinal fluid leaks and cost-benefit analysis in a retrospective study.
OBJECTIVE To determine the clinical efficacy and cost effectiveness of using the fibrin sealant (FS) Tisseel (Baxter Healthcare Corp., Deerfield, IL) for patients undergoing anterior cranial base, infratemporal, and retromastoid surgical procedures. METHODS A retrospective review was performed, comparing two matched populations of patients who underwent surgical procedures using anterior cran...
متن کاملCorrection: Fibrin Sealants in Dura Sealing: A Systematic Literature Review
[This corrects the article DOI: 10.1371/journal.pone.0151533.].
متن کاملVenous air embolism from Tisseel use during endoscopic cranial vault remodeling for craniosynostosis repair: a case report.
Venous air embolism (VAE) is a potential complication during cranial vault remodeling requiring early detection and prompt therapeutic intervention. The incidence of VAE has been reported to be as high as 82.6% during open craniectomy for craniosynostosis repair. On the other hand, two separate studies reported a much lower incidence of VAE (8% and 2%) during endoscopic strip craniectomy. As su...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Surgical neurology international
دوره 7 Suppl 3 شماره
صفحات -
تاریخ انتشار 2016