Overview and dosimetry of the Hanford Americium accident case.

نویسندگان

  • R E Toohey
  • R L Kathren
چکیده

Postmortem examinations of selected tissues from an individual who received a massive internal exposure to 241Am and succumbed to pre-existing cardiovascular disease 11 y later are summarized. Significant findings include acellularity of the marrow, marked peritrabecular fibrosis, and a lack of bone surface remodeling, confirmed by bone-surface alpha-spectrometry; tissue concentrations of 241Am that indicate bone and liver as the primary deposition sites, in general agreement with the new ICRP model, but not with the older models; a distribution of 241Am in soft tissues in general agreement with that observed in animals; and the absence of any other gross or microscopic pathological findings attributable to the exposure. Cumulative absorbed doses to the bone, bone surface, liver, and lung were 18, 520, 8, and 1.6 Gy, respectively. The probability of not observing a fatal cancer based on BEIR-IV risk factors for these absorbed doses was 12%.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hanford Site Vadose Zone Studies: An Overview

899 The Hanford Site is 1517 km2 (586 mi2) in size, located in a sparsely populated area in the rain shadow of the Cascade Mountains, adjacent to the Columbia River in southeastern Washington State (Fig. 1). The Hanford Site was set aside in the early 1940s by the U.S. Government to perform a top-secret mission, the Manhattan Project, for production of plutonium for atomic weapons used to end W...

متن کامل

Neutron dose per fluence and weighting factors for use at high energy accelerators.

In June 2007, the United States Department of Energy incorporated revised values of neutron weighting factors into its occupational radiation protection regulation Title 10, Code of Federal Regulations Part 835, as part of updating its radiation dosimetry system. This has led to a reassessment of neutron radiation fields at high energy accelerators such as those at the Fermi National Accelerato...

متن کامل

Overview of physical dosimetry methods for triage application integrated in the new European network RENEB.

PURPOSE In the EC-funded project RENEB (Realizing the European Network in Biodosimetry), physical methods applied to fortuitous dosimetric materials are used to complement biological dosimetry, to increase dose assessment capacity for large-scale radiation/nuclear accidents. This paper describes the work performed to implement Optically Stimulated Luminescence (OSL) and Electron Paramagnetic Re...

متن کامل

Modelling of Radioactive Pollutants: Application of the Detract Code System at the Hanford Scenario

INTRODUCTION The “Hanford Scenario” refers to an acute accidental release of radioactive I from the stack of the Hanford (USA) Purex Chemical Separations Plant that occurred between 2 and 5 of September 1963 (BIOMASS, 1999). From the environmental impact point of view it is a very interesting case study for the evaluation of computational systems that simulate the atmospheric dispersion, deposi...

متن کامل

Construction of a dose – response curve by induction of premature chromosome condensation for biological dosimetry

Premature Chromosome Condensation (PCC) appears to have a possible utility for biological dosimetry purposes. The PCC technique may be adapted for cases of suspicion of overexposure where sampling is performed at least one day after an accident. For this purpose, human blood samples were exposed in vitro to 60Co up to 10 Gy and the PCC technique was performed immediately after irradiation. Anal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Health physics

دوره 69 3  شماره 

صفحات  -

تاریخ انتشار 1995