Ghost peaks in reversed-phase gradient HPLC: a review and update.
نویسنده
چکیده
New examples and sources of ghost peaks in reversed-phase gradient HPLC are described and related to previous publications to give a broad perspective of ghost peak problems. In one new example the ghost peak was found to be due to mixing problems caused by a period of non-delivery of the stronger "solvent B" in a stepped gradient system. In a second example the ghost peak was due to plasticizer contamination of the organic solvent. This paper includes tips and recommendations for the consistent running of ghost-peak-free reversed-phase gradient HPLC.
منابع مشابه
A Preliminary Investigation Of Ghost Peaks In A Reversed-Phase Gradient HPLC System
This study involves a reversed-phase gradient HPLC related substances (impurity) analytical method, for a drug product. These types of analyses are of crucial importance because the data they supply is such that it might be part of qualifier information used by regulatory organisations to determine whether marketing authorisations applications are to be accepted or not. P bl b d i thi th d h t ...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملDevelopment and Validation of a Reversed-phase HPLC Method for Assay of the Decapeptide Cetrorelix Acetate in Bulk and Pharmaceutical Dosage Forms
A gradient reversed-phase high performance liquid chromatography (HPLC) method was developed for the assay of cetrorelix acetate, a synthetic decapeptide with gonadotropin-releasing hormone (GnRH) antagonistic activity used in infertility treatment. The HPLC method, which is used to determine cetrorelix in bulk and pharmaceutical dosage forms, was validated per ICH guidelines. The chromatograph...
متن کاملDevelopment and Validation of a Reversed-phase HPLC Method for Assay of the Decapeptide Cetrorelix Acetate in Bulk and Pharmaceutical Dosage Forms
A gradient reversed-phase high performance liquid chromatography (HPLC) method was developed for the assay of cetrorelix acetate, a synthetic decapeptide with gonadotropin-releasing hormone (GnRH) antagonistic activity used in infertility treatment. The HPLC method, which is used to determine cetrorelix in bulk and pharmaceutical dosage forms, was validated per ICH guidelines. The chromatograph...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. A
دوره 1052 1-2 شماره
صفحات -
تاریخ انتشار 2004