In vivo kinematics of the knee during weight bearing high flexion.

نویسندگان

  • Wei Qi
  • Ali Hosseini
  • Tsung-Yuan Tsai
  • Jing-Sheng Li
  • Harry E Rubash
  • Guoan Li
چکیده

Achieving high flexion is an objective of contemporary total knee arthoplasty; however little is known on the knee biomechanics at high flexion under weight-bearing conditions. This study investigates the 6DOF kinematics and tibiofemoral cartilage contact biomechanics of the knee during weight-bearing flexion from full extension to maximal flexion. Eight knees from seven healthy subjects with no history of injuries or chronic pain were recruited. The knees were MRI scanned to create 3D models of the tibia and femur, including their articular cartilage surfaces. The subjects were then imaged using a dual fluoroscopic image system while performing a weight-bearing quasi-static single-legged lunge from full extension to maximal flexion. The 6DOF kinematics and the articular cartilage contact locations were measured along the flexion path of the knee. The result indicated that the internal tibial rotation increased sharply at low flexion angles (full extension to 30°), maintained a small variation in the middle range of flexion (30-120°, and then sharply increased again at high flexion angles (120° to maximal flexion). The contact point moved similarly in the medial and lateral compartments before 120° of flexion, but less on the medial compartment at high flexion angles. The results indicated that the knee motion could not be described using one character in the entire range of flexion, especially in high flexion. The knee kinematic data in the entire range of flexion of the knee could be instrumental for designing new knee prostheses to achieve physical high flexion and improving rehabilitation protocols after knee injuries.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of using orthogonal fluoroscopic images to measure in vivo joint kinematics.

Accurately determining in vivo knee kinematics is still a challenge in biomedical engineering. This paper presents an imaging technique using two orthogonal images to measure 6 degree-of-freedom (DOF) knee kinematics during weight-bearing flexion. Using this technique, orthogonal images of the knee were captured using a 3-D fluoroscope at different flexion angles during weight-bearing flexion. ...

متن کامل

In vivo weight-bearing kinematics with medial rotation knee arthroplasty.

Knee arthroplasties are designed to accommodate flexion, axial rotation and anteroposterior (AP) translation. Axial rotation during extension varies, with some rotating platform devices allowing unrestricted rotation while some conforming fixed-bearing designs almost none. The purpose of this study was to examine in vivo kinematics of a fixed-bearing medial rotation-type arthroplasty (MRK) duri...

متن کامل

Differences in patellofemoral kinematics between weight-bearing and non-weight-bearing conditions in patients with patellofemoral pain.

Patellar maltracking is thought to be one source of patellofemoral pain. Measurements of patellar tracking are frequently obtained during non-weight-bearing knee extension; however, pain typically arises during highly loaded activities, such as squatting, stair climbing, and running. It is unclear whether patellofemoral joint kinematics during lightly loaded tasks replicate patellofemoral joint...

متن کامل

Influence of bi- and tri-compartmental knee arthroplasty on the kinematics of the knee joint

BACKGROUND The cruciate ligaments are important stabilizers of the knee joint and determine joint kinematics in the natural knee and after cruciate retaining arthroplasty.No in vitro data is available to biomechanically evaluate the ability of the anterior cruciate ligament (ACL) to maintain knee joint kinematics after bicruciate-retaining bi-compartmental knee arthroplasty (BKA).Therefore, the...

متن کامل

Does mobile-bearing knee arthroplasty motion change with activity?

BACKGROUND The purpose of this study was to evaluate the effect of mobile-bearing implant design and activity on knee arthroplasty kinematics during three activities of daily living. METHODS In vivo kinematics were analyzed using 3D model registration from fluoroscopic images of non-weightbearing knee flexion-extension, weight-bearing squatting and stair activities in 20 knees in 10 patients ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 46 9  شماره 

صفحات  -

تاریخ انتشار 2013