A conductimetric enzyme biosensor for uric acid detection has been developed. The uricase, as enzyme, is isolated from Candida utilis and immobilized on a nata de coco membrane-Pt electrode. The biosensor demonstrates a linear response to urate over the concentration range 1-6 ppm and has good selectivity properties. The response is affected by the membrane thickness and pH change in the range 7.5-9.5. The response time is three minutes in aqueous solutions and in human serum samples. Application of the biosensor to the determination of uric acid in human serum gave results that compared favourably with those obtained by medical laboratory. The operational stability of the biosensor was not less than three days and the relative error is smaller than 10%.
منابع مشابه
Solution Process Synthesis of High Aspect Ratio ZnO Nanorods on Electrode Surface for Sensitive Electrochemical Detection of Uric Acid
This study demonstrates a highly stable, selective and sensitive uric acid (UA) biosensor based on high aspect ratio zinc oxide nanorods (ZNRs) vertical grown on electrode surface via a simple one-step low temperature solution route. Uricase enzyme was immobilized on the ZNRs followed by Nafion covering to fabricate UA sensing electrodes (Nafion/Uricase-ZNRs/Ag). The fabricated electrodes showe...
متن کاملSelective potentiometric determination of uric acid with uricase immobilized on ZnO nanowires
In this study, a potentiometric uric acid biosensor was fabricated by immobilization of uricase onto zinc oxide (ZnO) nanowires. Zinc oxide nanowires with 80-150 nm in diameter and 900 nm to 1.5 μm in lengths were grown on the surface of a gold coated flexible plastic substrate. Uricase was electrostatically immobilized on the surface of well aligned ZnO nanowires resulting in a sensitive, sele...
متن کاملA Conductometric Urea Biosensor by Direct Immobilization of Urease on Pt Electrode
Urease was immobilized on platinum electrode both by chemical binding and electropolymerization.The conductometric urea biosensor thus prepared showed a detection limit of 4.9×10-5 M and linear dynamic range from 4.9×10-5 to 5.8×10-3 M for urea concentration when the enzyme is covalently immobilized on Pt electrodes. Conductometric transducers respo...
متن کاملThe Electropolymerization of Conductive Polymer Ppy-PANi on Gold Electrodes for Uric Acid Biosensor
Conducting polymers have emerged as potential candidates for biosensors. Due to their straightforward preparation methods, unique properties, and stability in air, conducting polymers have been applied to energy storage, electrochemical devices, memory devices, biosensors, and electro catalysts. Many research studies have been conducted on the use of conjugated polymers in the construction of c...
متن کاملAn amperometric cholesterol biosensor based on epoxy resin membrane bound cholesterol oxidase
BACKGROUND & OBJECTIVES The use of epoxy resin membrane as a support for immobilization of enzyme has resulted into improved sensitivity and stability of biosensors for uric acid, ascorbic acid and polyphenols. The present work was aimed to prepare an improved amperometric biosensor for determination of serum cholesterol required in the diagnostics and management of certain pathological conditi...