Role of three-dimensional endoanal ultrasound in assessing the anal sphincter morphology of female patients with chronic proctalgia

نویسندگان

  • Ya-Hong Xue
  • Shu-Qing Ding
  • Yi-Jiang Ding
  • Li-Qun Pan
چکیده

AIM To assess the role of three-dimensional endoanal ultrasound (3D-EAUS) for morphological assessment of the anal sphincter of female patients with chronic proctalgia (CP). METHODS In this unmatched case control study, 30 consecutive female patients with CP and 25 normal women (control group) were enrolled. 3D-EAUS was performed in all subjects. Thickness and length of internal anal sphincter (IAS), thickness of puborectalis muscle (PR), length of the external anal sphincter (EAS) plus PR, and puborectalis angle were measured and compared between the two groups. RESULTS Patients with CP had significantly shorter IAS length and greater PR thickness, as compared to those in normal individuals (26.28 ± 3.59 mm vs 28.87 ± 4.84 mm, P < 0.05 and 9.67 ± 1.57 mm vs 8.85 ± 0.97 mm, P < 0.05, respectively). No significant between-group differences were observed with respect to IAS thickness and the EAS plus PR length (P > 0.05). Puborectalis angle in the CP group was significantly decreased, both in resting (88.23° ± 1.81° vs 89.94° ± 2.07° in control group, P < 0.05) and straining (88.47° ± 3.32° vs 90.72° ± 1.87° in control group, P < 0.05) phases, which suggest the presence of paradoxical contraction of PR in patients with CP. In the CP group, no significant difference in puborectalis angle was observed between the resting and straining phases (88.23° ± 1.81° vs 88.47° ± 3.32° respectively, P > 0.05). CONCLUSION The association of greater PR thickness and paradoxical contraction of PR with CP suggest their potential value as markers of CP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The importance of ultrasound findings in the study of anal pain.

OBJECTIVE Endoanal ultrasonography can detect organic causes of anal pain without pathology on physical examination. The aim of this study is to evaluate the importance of endoanal ultrasonography in the diagnosis and therapeutic management of idiopathic and functional anal pain. MATERIAL AND METHODS Retrospective study, between 15 March 2005 and 15 June 2008, of all patients with proctalgia ...

متن کامل

Internal anal sphincter evaluation using 3D anal ultrasound.

A 42 year-old male, with no relevant medical history except surgery three years before for chronic anal fissure in another center (without information regarding type of surgery), attended outpatient clinic for several week-history of anal pain. The patient related a sudden anal pain without irradiation and without relationship with defecation that improved with flexion of the lower extremities....

متن کامل

Ultrasound imaging of the anal sphincter complex: a review.

Endoanal ultrasound is now regarded as the gold standard for evaluating anal sphincter pathology in the investigation of anal incontinence. The advent of three-dimensional ultrasound has further improved our understanding of the two-dimensional technique. Endoanal ultrasound requires specialised equipment and its relative invasiveness has prompted clinicians to explore alternative imaging techn...

متن کامل

Endosonographic evidence of injury to the internal anal sphincter after low anterior resection: long-term follow-up.

PURPOSE Transanal stapled anastomosis has been associated with continence disturbances and reduced postoperative anal sphincter function. The aim of the present work was to study the effect of transanal stapling on anal sphincter morphology by endoanal ultrasound. METHODS Thirty-nine consecutive patients undergoing stapled low anterior resection for rectal carcinoma were assessed. Each patien...

متن کامل

Development of an in-house endoanal ultrasound teaching phantom.

OBJECTIVES The aim of this study was to construct an anatomically correct phantom for visualization of anal sphincter complex structures. METHODS To ake an endoanal ultrasound phantom, we experimented with a variety of commercially available materials to simulate hyperechoic, hypoechoic, and isoechoic tissue consistency. We created external anal sphincter muscle and the levator plate using st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2017