Precise Half Life Measurements: the Case of C

نویسندگان

  • V. E. Iacob
  • V. Golovko
  • J. Goodwin
  • J. C. Hardy
  • N. Nica
  • H. I. Park
  • L. Trache
چکیده

V.E. Iacob, V. Golovko, J. Goodwin, J.C. Hardy, N. Nica, H.I. Park, L. Trache, and R.E. Tribble The half-life of C was measured as part of our program to test the unitarity of the CabibboKobayashi-Maskawa (CKM) matrix via 0 –> 0 superallowed β transitions; the case of C is of particular interest because of its higher sensitivity to the presence of scalar currents [1]. The C half-life has been measured twice before, with precisions of 0.10% [2] and 0.08% [3]. With our current techniques, we anticipate being able to improve that precision by more than a factor of two.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

BATHTUB HAZARD RATE DISTRIBUTIONS AND FUZZY LIFE TIMES

The development of life time analysis started back in the $20^{textit{th}}$ century and since then comprehensive developments have been made to model life time data efficiently. Recent development in measurements shows that all continuous measurements can not be measured as precise numbers but they are more or less fuzzy. Life time is also a continuous phenomenon, and has already been shown tha...

متن کامل

KINETICS AND MECHANISM OF AERIAL OXIDATION OF HYDROQUINONE IN A DEVELOPER SOLUTION AND DETERMINATION OF DEVELOPER'S HALF-LIFE AT 20°C

The aerial oxidation of hydroquinone in a freshly prepared developer solution at 20°C has been studied through the measurement of concentration changes by a spectrophotometric method. The concentration of consumed hydroquinone is directly proportional to time, and the equation tIl2 = C, / 0.0786 was obtained to calculate the half-life of the developer. In this equation, the half-life is in ...

متن کامل

HALO - a Java framework for precise transcript half-life determination

UNLABELLED Recent improvements in experimental technologies now allow measurements of de novo transcription and/or RNA decay at whole transcriptome level and determination of precise transcript half-lives. Such transcript half-lives provide important insights into the regulation of biological processes and the relative contributions of RNA decay and de novo transcription to differential gene ex...

متن کامل

New half-life measurement of 182Hf: improved chronometer for the early solar system.

The decay of 182Hf, now extinct, into stable 182W has developed into an important chronometer for studying early solar system processes such as the accretion and differentiation of planetesimals and the formation of the Earth and the Moon. The only 182Hf half-life measurements available were performed 40 years ago and resulted in an imprecise half-life of (9+/-2)x10(6) yr. We redetermined the h...

متن کامل

Comparison of the environmental flow assessment methods involving case studies of Karaj and Talar Rivers

Environmental flow is explained as the period of time, quantity and the amount of required water for maintaining the water, fresh, the river’s ecosystem, human beings’ welfare and the life depending on the water. The main goal of this paper is to investigate and compare the hydrological methods including Tennant, aquatic flow, Tessman, analysis of the flow duration curve and the flow duration c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006