The Disinfection Concentration Exponent *
نویسنده
چکیده
It is of course well recognized that the length of time required by a germicide to kill a given number of bacteria varies with the concentration of the substance. The relation between concentration and time can usually be expressed by the formula Ct k, often written in logarithmic form log t = log kn log c for convenience The obvious value of the concentration exponent n is that it gives direct information as to the effect of dilution upon the speed with which a disinfectant can kill. Silver nitrate and iodine, with n values of 1, can be diluted considerably without undue effect upon the time, whereas phenol, with a value of 6, rapidly loses its practical efficacy. Values for the concentration exponents have been determined for relatively few germicides, and the results obtained by different workers have often been discordant. It is always found, however, that the substances which have large n values belong to compounds which are surface active in character. In a recent papers Tilley has reported numerous values for concentration exponents, some of which, for alcohols, were as high as 12. Some attempt has been made to account for the existence of these high powers. Watson' has suggested that they may indicate chemical reactions of high order, but Buchanan and Fulmer' state that "such a value as is secured for n (if a constant is secured) should not be regarded as related directly to the order of the reaction, but as an arbitrary constant useful for comparative purposes." It has been mentioned that the disinfectants which have high concentration exponents possess surface-active properties. We know, too, that in any homologous series of substances, such as the alcohols, the surface tensions parallel thegermicidal properties. Presumably, therefore, the interfacial tension between germicide and cell also parallels the killing activity, and, if surface forces play any part in disinfection, will probably be the important factor. Attempts have been made to invoke such forces as being the active agents in killing, but the direct action has never been demonstrated and seems improbable.
منابع مشابه
Elimination of pathogenic bacteria using electrochemical process containing steel mesh electrode
The main objective of this study is removal of pathogenic bacteria using electrochemical process. The bactericidal effects of electrochemical system containing steel mesh electrode were evaluated from contaminated water with E. coli, Pseudomonas aeroginosa, Staphylococcus aureous and Streptococcus fecalis at various concentrations. Effect of current density, supporting electrolyte and pathogeni...
متن کاملComparison of the Effect of Perchlorine, Sodium Hypochlorite, and Electrochemical Method on Disinfection of Vegetables
Introduction: Many vegetables are eaten raw which can lead to the prevalence of food borne diseases if not properly sanitized. The aim of this study was to compare the effect of chlorine, bleach and multioxidant solution in disinfection of edible vegetables. Materials and Methods: In this experimental study, 100 g of vegetables (lettuce, basil and mint) was disinfected by sodium hypochlorite, ...
متن کاملProducts identified at an alternative disinfection pilot plant.
Many drinking water utilities have recently changed or are seriously considering changing their disinfection practice from chlorine to some alternative treatment process. However, most of these utilities are changing their disinfectants without evaluating chemical impacts. Therefore, a research cooperative agreement was developed with Jefferson Parish, LA, to evaluate four parallel streams trea...
متن کاملEfficiency of solar water disinfection photocatalized by titanium dioxide of varying particle size.
Titanium dioxide photocatalysed water disinfection is induced by the interaction of light with TiO(2), which generates highly reactive free hydroxyl radicals (OH(*)). These free radicals create lethal damage that leads to bacterial death. Normally, decreasing TiO(2) particle size increases the area of light interaction. This may possibly increase the concentration of OH(*) generated and hence i...
متن کاملبررسی گندزدایی پساب توسط فرایند ازناسیون کاتالیزوری با استفاده از نانو کامپوزیت کربنی و مقایسه اقتصادی آن با کلریناسیون
Background and purpose: Many conventional disinfection methods of effluents raise some health, efficiency and economic concerns. In order to increase the efficiency of disinfection of real effluent, in this study, the catalytic ozonation process was performed and economically compared with chlorination. Materials and methods: Magnetic activated carbon was used as acatalyst in a semi-continuo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Yale Journal of Biology and Medicine
دوره 12 شماره
صفحات -
تاریخ انتشار 1940