Control Performance Standard based Load Frequency Control of a two area Reheat Interconnected Power System considering Governor Dead Band nonlinearity using Fuzzy Neural Network

نویسندگان

  • R. Francis
  • I. A. Chidambaram
  • C. S. Indulkar
  • Baldev Raj
  • Sidhartha Panda
  • Cemal Ardil
  • M. J. Yao
  • R. R. Shoults
  • Jeong Woo Lee
چکیده

The frequency control of reheat interconnected two area power systems are mainly characterized by non-linearity and uncertainty. A hybrid neural network and fuzzy control is proposed for load frequency control in the power systems considering governor dead band (GDB) non-linearity. Fuzzy with neural network is employed to forecast the control input requirement and system's future output, based on the current Area Control Error (ACE) and the predicted change-of-ACE. The Control Performance Standard (CPS) criterion is adopted to the fuzzy controller design, thus improves the dynamic quality of system. The system was simulated and the output responses of frequency deviations in area 1 and area 2 and tie-line power deviations for 1% step-load disturbance in area 1 were obtained. The comparison of frequency deviations and tie-line power deviations for the two area interconnected thermal power system considering GDB nonlinearity with Redox Flow Batteries (RFB) reveals that the system with hybrid fuzzy neural controller enhances a better stability than that of system with integral controller.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of Fuzzy Logic Based PI Controller for DFIG-based Wind Farm Aimed at Automatic Generation Control in an Interconnected Two Area Power System

This paper addresses the design procedure of a fuzzy logic-based adaptive approach for DFIGs to enhance automatic generation control (AGC) capabilities and provide better dynamic responses in multi-area power systems. In doing so, a proportional-integral (PI) controller is employed in DFIG structure to control the governor speed of wind turbine. At the first stage, the adjustable parameters of ...

متن کامل

A Robust Discrete FuzzyP+FuzzyI+FuzzyD Load Frequency Controller for Multi-Source Power System in Restructuring Environment

In this paper a fuzzy logic (FL) based load frequency controller (LFC) called discrete FuzzyP+FuzzyI+FuzzyD (FP+FI+FD) is proposed to ensure the stability of a multi-source power system in restructured environment. The whale optimization algorithm (WOA) is used for optimum designing the proposed control strategy to reduce fuzzy system effort and achieve the best performance of LFC task. Further...

متن کامل

Performance Evaluation of Hybrid Intelligent Controllers in Load Frequency Control of Multi Area Interconnected Power Systems

This paper deals with the application of artificial neural network (ANN) and fuzzy based Adaptive Neuro Fuzzy Inference System(ANFIS) approach to Load Frequency Control (LFC) of multi unequal area hydro-thermal interconnected power system. The proposed ANFIS controller combines the advantages of fuzzy controller as well as quick response and adaptability nature of ANN. Area-1 and area-2 consist...

متن کامل

Load Frequency Control for a Two-area Interconnected Power System by Using Sliding Mode Controller

This paper presents the usage of sliding mode Control algorithm for the load frequency control in power systems. A sliding mode based load frequency controller is applied to a two-area power system. Non-reheat and reheat Thermal turbines are distributed in these two areas respectively. The nonlinearities such as governor dead band and generation rate constraint are included in the block diagram...

متن کامل

Hybrid evolutionary algorithm based fuzzy logic controller for automatic generation control of power systems with governor dead band non-linearity

Abstract: A new intelligent Automatic Generation Control (AGC) scheme based on Evolutionary Algorithms (EAs) and Fuzzy Logic concept is developed for a multiarea power system. EAs i.e. Genetic Algorithm–Simulated Annealing (GA–SA) are used to optimize the gains of Fuzzy Logic Algorithm (FLA)-based AGC regulators for interconnected power systems. The multi-area power system model has three diffe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012