Comparison of transverse dental changes induced by the palatally applied Frog appliance and buccally applied Karad's integrated distalizing system.

نویسندگان

  • Fatma Deniz Uzuner
  • Emine Kaygisiz
  • Fatih Unver
  • Tuba Tortop
چکیده

OBJECTIVE To compare the transverse dental changes induced by the palatally applied Frog appliance and buccally applied Karad's integrated distalizing system (KIDS). METHODS We evaluated the pre- and post distalization orthodontic models of 39 patients, including 19 treated using the Frog appliance, which is palatally positioned (Frog group), and 20 treated using KIDS, which is buccally positioned (KIDS group). Changes in intermolar and interpremolar distances and the amount of maxillary premolar and molar rotation were evaluated on model photocopies. Wilcoxon and Mann-Whitney U tests were used for statistical evaluations. A p-value of < 0.05 was considered statistically significant. RESULTS Significant distopalatal rotation of premolars and distobuccal rotation of molars were observed in Frog group (p < 0.05), while significant distopalatal rotation of molars (p < 0.05), with no significant changes in premolars, was observed in KIDS group. The amount of second premolar and first molar rotation was significantly different between the two groups (p < 0.05 and p < 0.001, respectively). Furthermore, expansion in the region of the first molars and second premolars was significantly greater in KIDS group than in Frog group (p < 0.001 for both). CONCLUSIONS Our results suggest that the type and amount of first molar rotation and expansion vary with the design of the distalization appliance used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Maxillary molar distalization with noncompliance intramaxillary appliances in Class II malocclusion. A systematic review.

OBJECTIVE To use published data to evaluate quantitatively the dental effects of noncompliance intramaxillary appliances in individuals with Class II malocclusion. MATERIALS AND METHODS A literature search was carried out identifing 13 prospective or retrospective clinical studies matching inclusion criteria. Only appliances with conventional anchorage designs were considered for the review. ...

متن کامل

Closure of an open bite using the 'Mousetrap' appliance: a 3-year follow-up.

Recently, skeletal anchorage devices have been used as anchorage units for upper molar intrusion as a way of correcting an anterior open bite malocclusion. To avoid the surgical procedures associated with the placement of miniplates in the zygomatic area, mini-implants may be inserted palatally or buccally in the alveolar process. However, consideration must be given to the potential risks of r...

متن کامل

Localization of Impacted Maxillary Canine Teeth: A Comparison between Panoramic and Buccal Object Rule in Intraoral Radiography

Objectives: This study aimed to compare the efficacy of panoramic radiography and the buccal object rule in intraoral periapical radiography for localization of impacted maxillary canine teeth. Methods: A total of 20 panoramic radiographs depicting 28 displaced maxillary canines were evaluated. The ratio of the mesiodistal width of the impacted canine to the mesiodistal width of the...

متن کامل

Effects of low-level laser therapy on the rate of orthodontic tooth movement.

OBJECTIVES To test the hypothesis that mechanical forces combined with low-level laser therapy stimulate the rate of orthodontic tooth movement. STUDY DESIGN This study was a double blind, randomized placebo/control matched pairs clinical trial to test the efficacy of GaAlAs low-level laser therapy (LLLT) on 12 young adult patients who required retraction of maxillary canines into first premo...

متن کامل

Fabrication and Evaluation of a Noncompliant Molar Distalizing Appliance: Bonded Molar Distalizer

OBJECTIVE Attempts to treat class II malocclusions without extraction in non-compliant patients have led to utilization of intraoral molar distalizing appliances. The purpose of this study was to investigate dental and skeletal effects of Bonded Molar Distalizer (BMD) which is a simple molar distalizing appliance. MATERIALS AND METHODS Sixteen patients (12 girls, four boys) with bilateral hal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Korean journal of orthodontics

دوره 46 2  شماره 

صفحات  -

تاریخ انتشار 2016