Correlation of functional MR imaging activation data with simple reaction times.
نویسندگان
چکیده
PURPOSE To determine the relationship between subject reaction times (RTs) and activation volume in the brain during visuomotor functional magnetic resonance (MR) imaging. MATERIALS AND METHODS Twenty-four subjects performed a simple RT task during single-event functional MR imaging, and RTs were recorded. The six subjects with the fastest RTs were designated the fast RT group, and the six subjects with the slowest RTs were designated the slow RT group. The data were processed with noncorrected height threshold (P <.001) for individual comparisons and corrected height threshold (P <.05) for group comparisons (t tests). The activation volumes in both occipital lobes, the left sensorimotor cortex, and the supplemental motor cortices were compared for the two groups. RESULTS The mean RT +/- SD was 342 msec +/- 20.15 for the fast RT group and 475 msec +/- 36.17 for the slow RT group (P <.0001). More voxels of activation were seen in the fast RT group than in the slow RT group in the occipital lobes, left sensorimotor cortices, and supplemental motor cortices on individual and group maps. This difference was statistically significant in the left sensorimotor (P =.03) and left visual (P =.05) cortices. In the right visual cortex, a trend toward more activation in the fast RT group was noted (P =.15). There was a negative correlation between RTs and activation volume in the left sensorimotor cortex (P =.048). CONCLUSION There was a greater activation volume in motor and visual cortices in the fast RT group than in the slow RT group.
منابع مشابه
Integrating fMRI data into 3D conventional radiotherapy treatmentplanning of brain tumors
Introduction: This study was aimed to investigate the beneficial effects of functional magnetic resonance imaging (fMRI) data in treatment planning for patients with CNS tumors in order to decrease the injury of functional regions of the brain followed by increase in life quality and survival of patients. This study pursues a novel approach in planning for the treatment of brai...
متن کاملOptimized co-registration method of Spinal cord MR Neuroimaging data analysis and application for generating multi-parameter maps
Introduction: The purpose of multimodal and co-registration In MR Neuroimaging is to fuse two or more sets images (T1, T2, fMRI, DTI, pMRI, …) for combining the different information into a composite correlated data set in order to visualization, re-alignment and generating transform to functional Matrix. Multimodal registration and motion correction in spinal cord MR Neuroimag...
متن کاملMapping of the sensorimotor cortex: functional MR and magnetic source imaging.
PURPOSE To assess the reliability and comparability of functional MR imaging and magnetic source imaging for mapping the somatosensory cortex. METHODS Parallel studies were performed in eight volunteer subjects in whom both hemispheres were measured with the use of painless tactile stimulation of the tip of each index finger. Magnetic source imaging was performed using a 37-channel biomagneto...
متن کاملEnhancement of BOLD-contrast sensitivity by single-shot multi-echo functional MR imaging.
Improved data acquisition and processing strategies for blood oxygenation level-dependent (BOLD)-contrast functional magnetic resonance imaging (fMRI), which enhance the functional contrast-to-noise ratio (CNR) by sampling multiple echo times in a single shot, are described. The dependence of the CNR on T2*, the image encoding time, and the number of sampled echo times are investigated for expo...
متن کاملRepeatability of Detecting Visual Cortex Activity in Functional Magnetic Resonance Imaging
Introduction As functional magnetic resonance imaging (fMRI) is too expensive and time consuming, its frequent implementation is difficult. The aim of this study is to evaluate repeatability of detecting visual cortex activity in fMRI. Materials and Methods In this study, 15 normal volunteers (10 female, 5 male; Mean age±SD: 24.7±3.8 years) attended. Functional magnetic resonance images were ob...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiology
دوره 226 1 شماره
صفحات -
تاریخ انتشار 2003