Biological safety of nasal thallium-201 administration: a preclinical study for olfacto-scintigraphy.

نویسندگان

  • Kohshin Washiyama
  • Hideaki Shiga
  • Kyoto Hirota
  • Asuka Tsuchida
  • Jupei Yamamoto
  • Sayaka Yagi
  • Tomokazu Yoshizaki
  • Mitsuru Furukawa
  • Ryohei Amano
  • Takaki Miwa
چکیده

Thallium-201/Nasal administration/Biological safety/Preclinical study. Nasal administration of thallium-201 (Tl) has previously been shown to be useful for the assessment of olfactory nerve connectivity in vivo. We assessed the biological effects of nasal Tl administration in mice to determine its safety before conducting clinical trials on humans. Tl uptake was evaluated in normal mice (n = 5) in vivo by using a high-resolution gamma camera and radiography 15 min, 1, 2 and 9 d after administration of TlCl to the right side of the nasal cavity (10 μl TlCl per nostril, 74 MBq/ml). Murine olfactory epithelial thickness (n = 5) was measured 9 d following nasal administration of TlCl. We assessed the odor detection ability of normal mice (n = 8) following nasal administration of TlCl to both sides of the nasal cavity, by observing cycloheximide solution avoidance behavior. We subsequently administrated TlCl (n = 4) or saline (n = 4) to both nostrils to assess the odor detection ability of mice following bilateral olfactory nerve transection. Tl uptake by the nasal cavity decreased immediately following nasal administration of Tl in normal mice. Nasal administration of Tl did not affect the olfactory epithelial thickness or the odor detection ability of normal mice. Recovery of odor detection ability following olfactory nerve transection was not significantly different between mice nasally administered with Tl, and mice administered with saline. Thus, nasal administration of Tl for the diagnosis of traumatic olfactory impairment did not produce harmful biological effects in vivo.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Serial Myocardial Imaging after a Single Dose of Thallium-201

Although thallium-201 exercise scintigraphy has been established for the detection of myocardial ischemia and viability, little is known regarding the myocardial thallium-201 kinetics during angioplasty. Herein, we report a 77-year old man with angina pectoris, in whom serial myocardial imaging after a single dose of thallium-201 was helpful in identifying not only the culprit lesion and myocar...

متن کامل

Dipyridamole thallium-201 scintigraphy for early risk stratification of patients after uncomplicated myocardial infarction.

OBJECTIVE To determine the safety and prognostic value of dipyridamole thallium-201 scintigraphy performed in patients within three to five days of acute myocardial infarction, including those receiving thrombolytic treatment. DESIGN A prospective study of dipyridamole thallium-201 scintigraphy in patients early after acute myocardial infarction. SETTING University hospital. PATIENTS 200 ...

متن کامل

Serial Myocardial Imaging after a Single Dose of Thallium-201

Although thallium-201 exercise scintigraphy has been established for the detection of myocardial ischemia and viability, little is known regarding the myocardial thallium-201 kinetics during angioplasty. Herein, we report a 77-year-old man with angina pectoris, in whom serial myocardial imaging after a single dose of thallium-201 was helpful in identifying not only the culprit lesion and myocar...

متن کامل

Cardiac Scintigraphy with Thallium-201 and Technetium Pyrophosphate

myocardial Scintigraphy ischemia can deor mc_mstrat_e mfarction. and It  has a higrs after onset of an mfarctl has a higrs after onset of an mfarctln and localizeh sensitivity in the first six to.twenty can belabelled pyrophosphate scan becomes four.  houuseful in the coronary care umt. The positive trction. Since the pyrophosphate scan 99mTc welve to twenty hours after onset of an becomes infa...

متن کامل

Thallium-201 scintigraphy in the evaluation of graft dysfunction in lung transplantation. Newark Beth Israel Medical Center Lung Transplant Group.

The object of this study was to evaluate graft dysfunction utilizing thallium-201 scintigraphy in patients who had undergone lung transplantation. We studied 11 patients who had undergone single-lung transplantation and had 44 evaluations for suspected graft dysfunction. All evaluations included a lung thallium-201 scan and chest radiography. In addition, 42 transbronchial biopsies, 19 gallium-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of radiation research

دوره 52 4  شماره 

صفحات  -

تاریخ انتشار 2011