Performance Analysis of an Existing BIPV System for Indian Climatic Conditions
نویسندگان
چکیده
In this communication, an attempt has been made for evaluating the performance of an existing BIPV system for Indian climatic conditions, considering four weather conditions (a, b, c and d type) for five different cities (New Delhi, Bangalore, Mumbai, Srinagar, and Jodhpur) of India. In this paper, first solar radiation is calculated on inclined roof (30), south, east and west facades (90) of the building and then fourteen different possible series and parallel combinations of PV integrated air ducts mounted on roof have been considered for the evaluation of thermal and electrical gain. It is found that, the average electrical efficiency of the system is 9.64%. Annual thermal and electrical gain obtained for the best combination (11 ducts are connected in parallel each having three PV modules) is 13.42 MWh and 4.38 MWh respectively for New Delhi condition. It is a self sustainable system where electrical energy is used for lighting purpose and thermal energy is used for space heating and drying.
منابع مشابه
HUMAN METRICS AFFECTING SUPPLY CHAIN PERFORMANCE: AN EMPIRICAL STUDY OF INDIAN MANUFACTURING ORGANIZATIONS
The manufacturing organizations today are having a competition of supply chain versus supply chain. Existing research work fails to relate human metrics with supply chain performance. The authors intend to empirically assess the effects of human metrics on supply chain performance in the context of Indian manufacturing organizations. A rigorous literature review has identified 12 variables. The...
متن کاملPerformance Study of a Solar Integrated Central Heating System of a Residential Building Using Trnsys- an Hourly Simulation Model (RESEARCH NOTE)
In this investigation, the performance of an existing heating system of a residential building incorporated with an array of solar thermal collectors was studied. For this purpose, transient systems simulation program model was assembled to estimate the hour-by-hour performance of the existing and the system equipped with the solar thermal collectors in terms of the provided space air condition...
متن کاملPerformance evaluation towards improved BiPV-Systems – Simulation of BiPV-systems installed on existing building facades using TRNSYS
The main focus of this work was the simulation and optimization of a BIPV-façade-system configuration through the development of simulations using the software ”TRNSYS”. First, several limitations and constraints within the TRNSYS framework needed to be solved to develop a reliable simulation environment. Various parameters were detected which are influencing the temperature distribution over a...
متن کاملHas the Public Health System Provided Adequate Financial Risk Protection for Child Birth Conditions – Evidences From an Eastern Indian State
Over the years, national and sub-national governments have introduced several initiatives to improve access to maternal and child health services in India. However, financial barriers have posed major constraints. Based upon the data of National Family Health Survey (NFHS) round 4 for Odisha state, our paper examines the out-of-pocket expenditure (OOPE) borne by households for accessing materna...
متن کاملDefining the Building-Integrated Photovoltaic Designs in architecture and urbanism with Emphasis on Usage in Iran
Demand of energy is more sensible now because of population growth and economic growth of countries. In order to increase of energy consumption around the world and environment pollution, attention to the renewable energy such as solar energy is inevitable. Building-integrated photovoltaic (BIPV) electric power systems not only produce electricity, they are also part of the building. For exam...
متن کامل