Diagnostic accuracy of saline infusion sonography in the evaluation of uterine cavity abnormalities prior to assisted reproductive techniques: a systematic review and meta-analyses.
نویسندگان
چکیده
BACKGROUND The diagnostic accuracy of a 2-D transvaginal scan, which is commonly employed to evaluate the regularity and shape of the uterine cavity in subfertile women, is relatively poor compared with other diagnostic modalities like saline infusion sonography (SIS) or hysteroscopy. SIS is a minimally invasive, cost-effective and acceptable diagnostic modality. Therefore the aim of this systematic review was to assess the diagnostic accuracy of SIS in the evaluation of the uterine cavity in subfertile women. METHODS A systematic review was conducted of diagnostic studies that compared SIS with hysteroscopy. Twenty relevant studies (including 1645 procedures) were identified and a subsequent meta-analysis was performed. Electronic databases were searched for relevant studies and references of relevant studies were cross checked. Validity was assessed and data were extracted independently by two authors. Heterogeneity was examined, studies were plotted in an ROC area and data were pooled. The main outcome measure was the diagnostic accuracy of saline infusion sonography. The pooled sensitivity, specificity, likelihood ratios and the post-test probabilities of saline infusion sonography on the prediction of uterine cavity abnormalities were calculated. RESULTS The pooled sensitivity of SIS in the detection of all intrauterine abnormalities was 0.88 (95% confidence interval (CI): 0.85-0.90). The pooled specificity was 0.94 (95% CI 0.93-0.96). The positive and negative likelihood ratios were 20.93 (95% CI: 9.06-48.34) and 0.15 (95% CI: 0.10-0.22), respectively. SIS had good accuracy in the detection of all intrauterine abnormalities (area under the summary receiver operating curve (sROC) = 0.97 ± 0.01). SIS also had a high pooled sensitivity and specificity in the detection of congenital uterine anomalies, 0.85 (95% CI: 0.79-0.90) and 1.00 (95% CI 0.99-1.00), respectively. However the limitations of the review include the heterogeneity amongst the included studies. CONCLUSIONS SIS is a highly sensitive investigative modality and comparable to the gold standard tool, hysteroscopy in the detection of intrauterine abnormalities in subfertile women. SIS is a highly sensitive and specific test in the diagnosis of uterine polyps, submucous myomas, uterine anomalies and intrauterine adhesions and can be used as a screening tool for subfertile patients prior to IVF treatment.
منابع مشابه
I-33: Role of Hysteroscopy in the Diagnosis and Infertility Treatment
Abnormalities of the uterine cavity can be a contributing cause of subfertility, and assessment of this factor has been suggested as a routine investigation in the evaluation of subfertile women. Hysterosalpingography has been used as the most common procedure in the investigation of infertility cause. Saline infusion sonohysterography can show uterine cavity abnormalities, which is highly sens...
متن کاملAccuracy of Two-Dimensional Transvaginal Sonography and Office Hysteroscopy for Detection of Uterine Abnormalities in Patients with Repeated Implantation Failures or Recurrent Pregnancy Loss
Objective: to compare diagnostic values of two dimensional trans-vaginal sonography (TVS) and office hysteroscopy (OH) for evaluation of endometrial pathologies in cases with repeated implantation failure (RIF) or recurrent pregnancy loss (RPL). Methods and Materials: This prospective study was performed in Royan institute from December 2013 to January 2015. TVS was performed before hysteroscop...
متن کاملI-34: Comparison between Hysteroscopy and Sonohysterography in Uterine Cavity Assessment
Intrauterine pathologies have been shown to be present in 25% of infertile patients.Structural abnormalities of the uterine endometrial cavity may affect the reproductive outcome adversely, by interfering with the implantation or causing spontaneous abortion. Intrauterine abnormalities may visualize using a variety of techniques. Including hysterosalpingography (HSG), transvaginal sonography (T...
متن کاملPnm-1: Applications of Hysterosonography for The Detection of Intracavitary Uterine Abnormalities
Hysterosonography (SHG) is a new noninvasive technique that involves the slow infusion of sterile saline solution into the uterus during ultrasound imaging. Expansion of endometrial cavity by SHG allows optimal visualization and plays an important role in the evaluation of abnormalities related to the uterus. The most common indications for hysterosonography are: abnormal uterine bleeding both ...
متن کاملSonohysterography for evaluation of endometrial abnormalities in breast cancer patients under tamoxifen therapy
Introduction: Tamoxifen may have secondary adverse effects on the endometrium. The aim of this study was to investigate the endometrial evaluation in women with breast cancer under tamoxifen therapy with Saline infusion Sonohysterography (SIS). Materials and Methods: This cross-sectional study was performed on 40 breast cancer patients under adjutant tamoxifen (20 mg/day for at least 6 months) ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Human reproduction update
دوره 21 2 شماره
صفحات -
تاریخ انتشار 2015