UNLABELLED We have addressed 2 major challenges of (82)Rb cardiac PET, noninvasive estimation of an accurate input function and absolute quantitation of myocardial perfusion, using a generalized form of least-squares factor analysis of dynamic sequences (GFADS) and a novel compartment analysis approach. METHODS Left and right ventricular (LV + RV) time-activity curves (TACs) were generated from 10 rest/stress studies, and 30 myocardial TACs were modeled to cover a range of clinical values. Two-dimensional PET Monte Carlo simulations of the LV, RV, myocardium, and other organs were generated separately and combined using the above TACs to form 30 realistic dynamic (82)Rb studies. LV and RV TACs were estimated by GFADS and used as input to a 2-compartment kinetic analysis that estimates parametric maps of myocardial tissue extraction (k(1)) and egress (k(2)), as well as LV + RV contributions (f(v), r(v)), by orthogonal voxel grouping. In addition, 13 patients were injected with 2.22 +/- 0.19 GBq (60 +/- 5 mCi) of (82)Rb and imaged dynamically for 6 min at rest and during dipyridamole stress. RESULTS In Monte Carlo simulations, GFADS yielded estimates of the 3 factors and corresponding factor images, with average errors of -4.2% +/- 6.3%, 3.5% +/- 4.3%, and 2.0% +/- 5.5% in the LV, RV, and myocardial factor estimates, respectively. The estimates were significantly more accurate and robust to noise than those obtained using TACs based on manually drawn volumes of interest (P < 0.01). The 2-compartment approach yielded accurate k(1), k(2), f(v), and r(v) parametric maps; the average error of estimates of k(1) was 6.8% +/- 3.6%. In all patient studies, our approach yielded robust estimates of k(1), k(2), f(v), and r(v), which correlated very well with the status of the subject and the catheterization results. CONCLUSION Quantitative dynamic (82)Rb PET using generalized factor analysis of dynamic sequences and compartmental modeling yields estimates of parameters of absolute myocardial perfusion and kinetics with errors of <9%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coronary flow and flow reserve by PET simplified for clinical applications using rubidium-82 or nitrogen-13-ammonia.

UNLABELLED To validate routine, noninvasive determination of absolute myocardial perfusion and coronary flow reserve (CFR), cardiac PET was performed in animals using a simplified imaging protocol, high-dose dipyridamole and a simplified quantitative algorithm specific for 82Rb and 13N-ammonia. METHODS One hundred thirty-five PET scans were obtained in eight dogs after intravenous 13N-ammonia...

متن کامل

Variability and reproducibility of rubidium-82 kinetic parameters in the myocardium of the anesthetized canine.

UNLABELLED Kinetic analysis of 82Rb dynamic PET data produces quantitative measures which could be used to evaluate ischemic heart disease. These measures have the potential to generate objective comparisons of different patients or the same patient at different times. To achieve this potential, it is essential to determine the variability and reproducibility of the kinetic parameters. METHOD...

متن کامل

Cardiac PET/CT with Rb-82: optimization of image acquisition and reconstruction parameters

BACKGROUND Our aim was to characterize the influence of time-of-flight (TOF) and point spread function (PSF) recovery corrections, as well as ordered subset expectation maximization (OSEM) reconstruction parameters, in 82Rb PET/CT quantification of myocardial blood flow (MBF) and myocardial flow reserve (MFR). Rest and stress list-mode dynamic 82Rb PET acquisition data from 10 patients without ...

متن کامل

Use of wavelet transforms in analysis of time-activity data from cardiac PET.

UNLABELLED Because of its intrinsic quantitative properties, PET permits measurement of myocardial perfusion and metabolism in absolute terms (i.e., mL/g/min). However, quantification has been limited by errors produced in image acquisition, selection of regions of interest, and data analysis. The goal of this study was to evaluate a newly developed, novel, wavelet-based noise-reduction approac...

متن کامل

Noninvasive quantification of regional myocardial perfusion with rubidium-82 and positron emission tomography. Exploration of a mathematical model.

Positron emission tomography (PET) centers without cyclotrons use generator-produced rubidium-82 (82Rb) for assessment of myocardial perfusion. The aim of the present study was to determine whether myocardial blood flow could be assessed quantitatively with 82Rb and PET. Because the myocardial extraction fraction of 82Rb varies inversely and nonlinearly with flow and cannot be measured convenie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 46 8  شماره 

صفحات  -

تاریخ انتشار 2005