Influence of thermal treatments on the response of sand radiation detectors for high-dose dosimetry.
نویسندگان
چکیده
The dosimetric properties of sand from Brazilian beaches have shown to be useful for high-dose dosimetry. The thermoluminescent (TL) and electron paramagnetic resonance (EPR) techniques were utilised, and the sand samples were recently studied in relation to their main dosimetric properties. The EPR signal at g = 1.999 grows significantly in function of the absorbed dose, and the TL peaks appear at 110 and 170 degrees C. However, these sand samples present a post-irradiation thermal decay at room temperature, which is a problem for dosimetric procedures. In this study, sand samples have been studied in relation to different thermal treatments. Post-irradiation treatments were performed at 50 degrees C up to 230 degrees C.
منابع مشابه
Achievable accuracy in brain tumors by in vivo dosimetry with diode detectors
ABSTRACT Background: In vivo measurements of applied dose during radiotherapy treatment, is important to ensure accurate dose delivery to patients. Uncertainty in dose delivery should fall within ±5% of the prescribed dose as recommended by ICRU. Assessment of dose for radiotherapy applications performed with various types of detectors. In this study, semiconductor diodes were used which have s...
متن کاملVerification of the Accuracy of the Delivered Dose in Brain Tumors by in Vivo Dosimetry Using Diode Detectors
Introduction: During radiotherapy, high accuracy in the dose delivery is required because there is a strong relationship between the absorbed dose, local tumor control and particularly the normal tissue damage. In many institutions, in vivo dosimetry using diodes is performed to check the actual dose delivered. In general, the uncertainty in the dose delivered should fall within ± 5% of the...
متن کاملPhoton dosimetry based on selective data sampling for the NaI(TL) detector
Radiation detection is essential for determining of radiation dose. Depend on the detector and dosimetry method, detection process is performed in different levels. Pulse counting is the first level of detection. Typically, the output of a radiation detector for determining value of the radiation dose cannot be used directly. Through changing the response function or the readout detector, is tr...
متن کاملDimethyl sulfoxide, diethyl fumarate solution for high dose dosimetry
Background: Dosimetry is a fundamental part of the radiation processing industry. Aqueous inorganic dosimeters have been used for gamma radiation dosimetry such as standard ferrous sulfate dosimeter. The purpose of this study was to investigate the effect of gamma radiation on the diethyl fumarate DEF in dimethyl sulfoxide DMSO solution and its possible use in chemical dosimetry. Materials and ...
متن کاملEvaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT
Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiation protection dosimetry
دوره 120 1-4 شماره
صفحات -
تاریخ انتشار 2006