Quantitative comparison of myocardial fiber structure between mice, rabbit, and sheep using diffusion tensor cardiovascular magnetic resonance
نویسندگان
چکیده
BACKGROUND Accurate interpretations of cardiac functions require precise structural models of the myocardium, but the latter is not available always and for all species. Although scaling or substitution of myocardial fiber information from alternate species has been used in cardiac functional modeling, the validity of such practice has not been tested. METHODS Fixed mouse (n = 10), rabbit (n = 6), and sheep (n = 5) hearts underwent diffusion tensor imaging (DTI). The myocardial structures in terms of the left ventricular fiber orientation helix angle index were quantitatively compared between the mouse rabbit and sheep hearts. RESULTS The results show that significant fiber structural differences exist between any two of the three species. Specifically, the subepicardial fiber orientation, and the transmural range and linearity of fiber helix angles are significantly different between the mouse and either rabbit or sheep. Additionally, a significant difference was found between the transmural helix angle range between the rabbit and sheep. Across different circumferential regions of the heart, the fiber orientation was not found to be significantly different. CONCLUSIONS The current study indicates that myocardial structural differences exist between different size hearts. An immediate implication of the present findings for myocardial structural or functional modeling studies is that caution must be exercised when extrapolating myocardial structures from one species to another.
منابع مشابه
Helical myofiber orientation after myocardial infarction and left ventricular surgical restoration in sheep.
OBJECTIVES It has been proposed that successful left ventricular surgical restoration should restore normal helical myofiber orientation. A magnetic resonance imaging technique, magnetic resonance diffusion tensor imaging, has been developed to measure myocyte orientation. By using magnetic resonance diffusion tensor imaging, this study tested the hypothesis that (1) myocyte orientation is alte...
متن کاملThree-dimensional diffusion tensor microscopy of fixed mouse hearts.
The relative utility of 3D, microscopic resolution assessments of fixed mouse myocardial structure via diffusion tensor imaging is demonstrated in this study. Isotropic 100-microm resolution fiber orientation mapping within 5.5 degrees accuracy was achieved in 9.1 hr scan time. Preliminary characterization of the diffusion tensor primary eigenvector reveals a smooth and largely linear angular r...
متن کاملMagnetic resonance myocardial fiber-orientation mapping with direct histological correlation.
Functional properties of the myocardium are mediated by the tissue structure. Consequently, proper physiological studies and modeling necessitate a precise knowledge of the fiber orientation. Magnetic resonance (MR) diffusion tensor imaging techniques have been used as a nondestructive means to characterize tissue fiber structure; however, the descriptions so far have been mostly qualitative. T...
متن کاملMyocardial fiber orientation mapping using reduced encoding diffusion tensor imaging.
A precise knowledge of the myocardial fiber architecture is essential to accurately understand and interpret cardiac electrical and mechanical functions. Diffusion tensor imaging has been used to noninvasively and quantitatively characterize myocardial fiber orientations. However, because the approach necessitates diffusion to be measured in multiple encoding directions and frequently at multip...
متن کاملFiber architecture in remodeled myocardium revealed with a quantitative diffusion CMR tractography framework and histological validation
BACKGROUND The study of myofiber reorganization in the remote zone after myocardial infarction has been performed in 2D. Microstructural reorganization in remodeled hearts, however, can only be fully appreciated by considering myofibers as continuous 3D entities. The aim of this study was therefore to develop a technique for quantitative 3D diffusion CMR tractography of the heart, and to apply ...
متن کامل