Methods for monitoring patient dose in dental radiology.
نویسندگان
چکیده
Different types of X-ray equipment are used in dental radiology, such as intra-oral, panoramic, cephalometric, cone-beam computed tomography (CBCT) and multi-slice computed tomography (MSCT) units. Digital receptors have replaced film and screen-film systems and other technical developments have been made. The radiation doses arising from different types of examination are sparsely documented and often expressed in different radiation quantities. In order to allow the comparison of radiation doses using conventional techniques, i.e. intra-oral, panoramic and cephalometric units, with those obtained using, CBCT or MSCT techniques, the same quantities and units of dose must be used. Dose determination should be straightforward and reproducible, and data should be stored for each image and clinical examination. It is shown here that air kerma-area product (P(KA)) values can be used to monitor the radiation doses used in all types of dental examinations including CBCT and MSCT. However, for the CBCT and MSCT techniques, the methods for the estimation of dose must be more thoroughly investigated. The values recorded can be used to determine the diagnostic standard doses and to set diagnostic reference levels for each type of clinical examination and equipment used. It should also be possible to use these values for the estimation and documentation of organ or effective doses.
منابع مشابه
Absorbed dose to peripheral organs during different methods of dental radiology using radiation estimation models
Introduction: Dental radiography as one of the most frequent type of radiological examinations is accepted for medical investigations due to their significant benefits nevertheless using ionizing radiation. It has lower radiation dose compared to another radiological examination but because of its high application for children, radiation dose needs attention. Based on affectin...
متن کاملEvaluation of the Observance of Radiation Protection Principles in Dentistry Centers in Kermanshah province (West Iran)
Introduction: Radiography plays an important role in the diagnosis of oral and dental disease and one of the most common diagnostic procedures in dentistry. Recent reports have raised concern about the increased use of ionizing radiation in dental imaging and the possibility of cancers. The effective dose of some dental radiographic examinations is high enough, so appropriate ...
متن کاملAssessment of patient entrance skin dose (ESD) and effective dose (ED) for the most common interventional radiological exams at Mazandaran hospital
Introduction: Nowadays we are witnessing an exponential application of interventional radiology techniques in various communities as well as Iran. Radiological technique is regarded as the 2nd contributing factor in increasing the amount of public doses in various societies. So that related radiation protection organization has recommended measuring patient d...
متن کاملDose Reduction Methods in Chest Computed Tomography
Introduction: Computed tomography is one of the most powerful tools for investigating thorax disease, because it shows progression of lung disease much clearer than chest radiography. Technical advances in CT scanners have led to some abilities for CT scanners such as coverage of larger volume, lower noise and ability for acquiring image in one respiratory phase. However, this will be accompani...
متن کاملارزیابی دز ورودی پوستی و دز مؤثر بیماران در معمول ترین آزمون های رادیولوژی
Introduction: Nowadays, we are witnessing a progressive application of radiology techniques in various communities as well as in Iran. Medical radiological examinations are one of the important sources of public radiological dose. Entrance skin doses and effective doses for patients in diagnostic radiology examinations should be assessed for the imaging techniques optimization and patient&rsquo...
متن کاملCommon Positioning Errors in Digital Panoramic Radiographies Taken In Mashhad Dental School
Introduction: The present study was aimed at evaluating common positioning errors on panoramic radiographs taken in the Radiology Department of Mashhad Dental School. Materials and methods: The study sample included 1,990 digital panoramic radiographs taken in the Radiology Department of Mashhad Dental School by a Planmeca Promax (Planmeca Oy, Helsinki, Finland), during a 2-year period (2010–20...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiation protection dosimetry
دوره 139 1-3 شماره
صفحات -
تاریخ انتشار 2010